210 CBAI-01 bipolar analog IO adapter module
Parameter
12.20 AI1 scaled at AI1 max
32.05 Supervision 1 function
32.06 Supervision 1 action
32.07 Supervision 1 signal
32.09 Supervision 1 low

Diagnostics

LEDs

The adapter module has one diagnostic LED.
Color
Green

Technical data

Installation
Degree of protection
Ambient conditions
Package
Analog inputs (80...82, 83...85)
Maximum wire size
Input voltage (AI+ and AI-)
Input resistance
Optional cable shield connection
Analog outputs (86...88, 89...91)
Maximum wire size
Output voltage (AO+ and
AGND)
Output resistance
Recommended load
Inaccuracy
Optional cable shield connection
Analog output scale switch
ON state
OFF state
Isolation areas
Setting
50
Low
Fault
AI1
0.4
Into SLOT 2 on the drive control unit
IP20
See the drive technical data.
Cardboard
2
1.5 mm
-10 V ... +10 V
> 200 kohm
1.5 mm
2
0 V ... +10 V
< 20 ohm
> 10 kohm
typical ±1%, max. ±1.5% of full scale
0.5 V ... 9.5 V range in use
0 V ...10 V range in use
Default
50
Disabled
No action
Frequency
0.00
Description
The adapter module is powered up.