NEC Express5800/R120g-1E Maintenance Manual page 199

Express server
Hide thumbs Also See for Express5800/R120g-1E:
Table of Contents

Advertisement

Chapter 3 Appendix
BMC Message on Lower LCD Line
CPU1-DIMM Area Temperature Lower
Non-Critical
CPU1-DIMM Area Temperature Upper
Non-Critical
CPU1-DIMM Area Temperature Lower
Critical
CPU1-DIMM Area Temperature Upper
Critical
CPU2-DIMM Area Temperature Lower
Non-Critical
CPU2-DIMM Area Temperature Upper
Non-Critical
CPU2-DIMM Area Temperature Lower
Critical
CPU2-DIMM Area Temperature Upper
Critical
Processor1 Thermal Control Upper
Non-Critical
Processor1 Thermal Control Upper
Critical
Processor2 Thermal Control Upper
Non-Critical
Processor2 Thermal Control Upper
Critical
DUMP Request !
Power Supply1 Failure detected
Power Supply2 Failure detected
Power Supply1 AC lost
Power Supply2 AC lost
Processor Missing
Cause
A temperature abnormality was
detected.
The dump button was pressed.
A power supply unit abnormality
occurred.
No CPUs are installed.
Express5800/R120g-1E Maintenance Guide
1. POST Error Message
Solution
The cooling fan has failed or is
clogged.
Contact your sales representative.
Wait until collecting the memory dump
data has finished.
Make sure that the power cord is
plugged in. If this does not resolve the
problem, contact your sales
representative.
Contact your sales representative.