NEC Express5800/R120g-1E Maintenance Manual page 193

Express server
Hide thumbs Also See for Express5800/R120g-1E:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
C040
SROM data read error
C061
1st SMBus device Error
detected.
C062
2nd SMBus device Error
detected.
C063
3rd SMBus device Error
detected.
C064
4th SMBus device Error
detected.
C065
5th SMBus device Error
detected.
C066
6th SMBus device Error
detected.
C067
7th SMBus device Error
detected.
C068
8th SMBus device Error
detected.
C101
BMC Memory Test
Failed.
C102
BMC Firmware Code
Area CRC check Failed.
C103
BMC core hardware failure.
BMC IBF or OBF check failed. An error was detected while
C104
C105
BMC SEL area full.
C10B
BMC operational code
corrupted.
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC FRU
corrupted.
C10E
BMC SDR Repository empty.
C10F
IPMB signal lines do not
respond.
C110
BMC FRU device failure.
BMC SDR Repository failure. Failure was detected in SROM that
C111
C112
BMC SEL device failure.
C113
BMC RAM test error.
C114
BMC Fatal hardware error.
C115
Management controller
not responding
C116
Private I2C bus not
responding.
C117
BMC internal exception
C118
BMC A/D timeout error.
C119
SDR repository corrupt.
C11A
SEL corrupt.
Cause
An error was detected while
reading data on FRU.
An error was detected on 1st SM
Bus.
An error was detected on 2nd SM
Bus.
An error was detected on 3rd SM
Bus.
An error was detected on 4th SM
Bus.
An error was detected on 5th SM
Bus.
An error was detected on 6th SM
Bus.
An error was detected on 7th SM
Bus.
An error was detected on 8th SM
Bus.
An error was detected on BMC.
accessing BMC.
There is not enough space to store
the system event log.
Flash Memory for BMC is faulty.
An illegality was detected while
updating BMC firmware.
An illegality was detected in FRU
containing the device information.
An error was detected on BMC
SDR.
Failure of Satellite Management
Controller was detected.
An error was detected in FRU that
contains device information.
stores the SDR.
Device failure was detected in BMC
SEL.
An error was detected in BMC
RAM.
A hardware error was detected in
BMC.
Management controller does not
respond.
Private I2C bus does not respond.
BMC internal error was detected.
BMC A/D timeout error was
detected.
BMC error or illegal SDR data was
detected.
BMC error or illegal system event
log data was detected.
Express5800/R120g-1E Maintenance Guide
1. POST Error Message
Solution
Contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Run Offline Tools (Chapter 1, 9. Offline Tools)
and clear the event logs.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Update the BMC firmware.
If the same error is detected repeatedly,
contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
193

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800 seriesExp803

Table of Contents