Toro Groundsmaster 360 Operator's Manual page 24

4-wheel drive multi-purpose machine with cab
Hide thumbs Also See for Groundsmaster 360:
Table of Contents

Advertisement

Figure 18
1. Wire harness and connectors
4. Connect the Diagnostic ACE display tool connector to
the diagnostic connector
Note: Make sure correct overlay decal is positioned
on Diagnostic ACE display.
Figure 19
1.
Diagnostic ACE
5. Turn the key switch to the On position, but do not
start the machine.
Note: The red text on the overlay decal refers to input
switches and the green text refers to outputs.
6. The "inputs displayed" LED, on the lower right
column of the Diagnostic ACE, should be illuminated.
If the "outputs displayed" LED is illuminated, press
the toggle button, on Diagnostic ACE, to change LED
to "inputs displayed".
g018321
(Figure
19).
The Diagnostic ACE will illuminate the LED associated
with each of the inputs when that input switch is closed.
7. Individually, change each of the switches from open
to closed (i.e., sit on seat, engage traction pedal, etc.),
and note that the appropriate LED on Diagnostic ACE
will blink on and off when corresponding switch is
closed. Repeat this for all switches that you can change
by hand.
8. If a switch is closed and the appropriate LED does not
turn on, check all wiring and connections to the switch
and/or check the switch with an ohm meter. Replace
any defective switch and repair any defective wiring.
Note: The Diagnostic ACE also has the ability to detect
which output solenoids or relays are turned on. This is a quick
way to determine the source of the machine's malfunction.
Verifying Output Function
1. Park the machine on a level surface, lower the
attachment, stop the engine, and engage the parking
brake.
2. Raise the seat.
3. Locate wire harness and connectors near controller.
4. Carefully unplug loopback connector from harness
connector.
5. Connect the Diagnostic ACE connector to the
appropriate harness connector. If the machine is
equipped with a front attachment, it will have two
controllers.
Note: Make sure correct overlay decal is positioned
on Diagnostic ACE.
6. Turn the key switch to the ON position, but do not
start machine.
Note: The red text on the overlay decal refers to input
switches and the green text refers to outputs.
7. The "outputs displayed" LED, on lower right column
of Diagnostic ACE, should be illuminated. If the
"inputs displayed" LED is illuminated, press the toggle
button, on the Diagnostic ACE, to change the LED to
"outputs displayed".
Note: It may be necessary to toggle between "inputs
displayed" and "outputs displayed" several times to do
the following step. To toggle back and forth, press
the toggle button once. This may be done as often as
required. Do not hold the button.
8. Sit on the seat and attempt to operate the desired
function of the machine. The appropriate output
LEDs should illuminate to indicate that the ECM is
turning on that function.
Note: If the correct output LEDs do not illuminate, verify
that the required input switches are in the necessary positions
to allow that function to occur. Verify correct switch function.
24

Advertisement

Table of Contents
loading

This manual is also suitable for:

31236

Table of Contents