GE BAKER HUGHES Masoneilan SVi 1000 Quick Start Manual page 29

Table of Contents

Advertisement

4. Thread the take-off rod to the actuator stem connector (Figure 14).
Install 1/4-20 x 1 Nut
Turnbuckle Length as per
Table 3
5. Attach the right hand threaded rod end to the lever using a 1⁄4 - 20 x 1" cap screw
and nut (Figure 14).
6. Thread the right hand lock nut and turnbuckle onto the right hand rod end
approximately two turns. Turnbuckle length is a function of actuator size. Refer to
Table 3 on page 28.
7. Secure the magnet housing assembly, including the lever and right hand rod end,
to the bracket using four M5 X 10 mm flat head screws.
8. Attach the left hand threaded rod end to the take-off rod with 1⁄4 - 20 UNC nut and
thread the left hand lock nut onto the rod end.
9. Move the valve to its closed position. For air to:
10. Thread the turnbuckle onto the left hand threaded rod end (Figure 14).
11. Adjust the turnbuckle until the hole in the lever is aligned with the alignment hole
in the bracket. Tighten both turnbuckle lock nuts (Figure 14).
© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
Take Off Rod
Figure 14 SVi1000 Take Off Rod Mounting
Close: Requires using air pressure in the actuator to fully stroke the actuator.
Open: Vent the actuator of air pressure.
Right Hand Rod
End
Left Hand Rod End: Install 1/4-20 x 1 Nut
and Cap Screw
Masoneilan SVi1000 Positioner Quick Start Guide =| 29
Magnet Housing
Install 1/4-20 x
1 Cap Screw

Advertisement

Table of Contents
loading

Table of Contents