NEC EXP803 Maintenance Manual page 188

Express server
Hide thumbs Also See for EXP803:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC FRU
corrupted.
C10E
BMC SDR Repository empty.
C10F
IPMB signal lines do not
respond.
C110
BMC FRU device failure.
C111
BMC SDR Repository failure.
C112
BMC SEL device failure.
C113
BMC RAM test error.
C114
BMC Fatal hardware error.
C115
Management controller
not responding
C116
Private I2C bus not
responding.
C117
BMC internal exception
C118
BMC A/D timeout error.
C119
SDR repository corrupt.
C11A
SEL corrupt.
C11B
BMC Mezzanine card is not
found.
C11C
BMC Mezzanine partition is
invalid.
C11D
BMC is in Forced Boot Mode.
Communication with BMC was
C11E
failed in previous boot
Backup Data of BMC Mezzanine
C11F
card has corrupted.
BMC Runtime FW corrupted.
C120
BMC Force Update FW corrupted. An error occurred on BMC Force
C121
BMC Configuration area
C122
corrupted.
BMC eMMC inaccessible.
C123
BMC eMMC mode error.
C125
BMC eMMC partition corrupted.
C126
BMC eMMC format corrupted.
C127
BMC is in Update Mode.
C128
C300
Out-of-band setup
configuration failure
188
Cause
An illegality was detected while
updating BMC firmware.
An illegality was detected in FRU
containing the device information.
An error was detected on BMC
SDR.
Failure of Satellite Management
Controller was detected.
An error was detected in FRU that
contains device information.
Failure was detected in SROM that
stores the SDR.
Device failure was detected in BMC
SEL.
An error was detected in BMC
RAM.
A hardware error was detected in
BMC.
Management controller does not
respond.
Private I2C bus does not respond.
BMC internal error was detected.
BMC A/D timeout error was
detected.
BMC error or illegal SDR data was
detected.
BMC error or illegal system event
log data was detected.
BMC Mezzanine card is not
installed.
A format error was detected in BMC
Mezzanine card.
Detected that BMC is in Forced
Boot Mode.
Communication with BMC was
failed in previous boot
Inconsistency was found on BMC
mezzanine card.
An error occurred on BMC Runtime
FW.
Update FW.
An error occurred on BMC
Configuration area.
Failed to access to BMC eMMC.
BMC eMMC mode error
An error occurred on BMC eMMC
partition.
A format error occurred on BMC
eMMC.
BMC is in update mode.
An error was detected while
accessing BMC Mezzanine card.
Express5800/R120f-1E Maintenance Guide
1. POST Error Message
Solution
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Update the BMC firmware.
If the same error is detected repeatedly,
contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on
motherboard. If the same error is detected
repeatedly, contact your sales representative.
Unplug the power cord, wait for 30 seconds,
and restart the server. If the same error is
detected repeatedly, contact your sales
representative.
Contact your sales representative.
Disconnect the power cord, wait for at least 30
seconds, and then restart the server. If the
same error is detected again, contact your
sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/r120f-1eExpress5800 series

Table of Contents