Power Supply Specifications
Item
Input power supply voltage
Power consumption
Connector Conversion Box only
Inrush current
Permissible instantaneous power failure time
Applicable GOTs
Abbreviations
GOT 1000
GT16 Handy GOT
Internal Relay Contact Specifications
Item
Contact rating
Operation switch
10mA/24VDC
Each contact coordinates the operation switch status of Pressed (close)/Not pressed (open).
SW1 to SW6
(resistance load only)
When the external cable is not connected, contacts are always open regardless of the switch status.
Each contact coordinates the emergency stop switch status of Pushed (open)/Return (close). When the external cable is not
connected, contacts are always open regardless of the emergency stop switch status. Causing a short circuit of the ESB
terminal which is close to the ESA terminal by a short pin (prepared by user) enables to set each contact in the close status
1A/24VDC
even if the external connection cable is not connected.
Emergency stop
(resistance load)
When using the short-circuited ESB terminal which is close to the ESA terminal
switch
0.3A/24VDC
 Contacts are normally operated in the close status. When pushing the emergency stop switch, the contacts become open.
ES1A to ES3A
(induction load)
 In the following situations, contacts are closed regardless of the status of the emergency stop switch and the external cable.
- When GT16H-CNB-42S is turned OFF.
- When GT16H-CNB-42S is not supplied with the power supply (DC24V).
1A/24VDC
Grip switch
(resistance load)
Each contact coordinates the grip switch status of Pressed (close)/Not pressed (open).
DSW1, DSW2
0.3A/24VDC
When the external cable is not connected, contacts are always open regardless of the grip switch status.
(induction load)
Each contact coordinates the position of the keylock switch.
Keylock switch
1A/24VDC
 When the key is on the left: KSW1 and KSWC are short-circuited.
(2-position switch)
(resistance load)
KSWC, KSW1,
0.3A/24VDC
 When the key is on the right: KSW2 and KSWC are short-circuited.
KSW2
(induction load)
When the external cable is not connected, contacts are always open regardless of the keylock switch.
*1 The system may not match the safety standards. Before using the system, please check the safety standards which are required.
3. Part Names and External Dimensions
The name and the external dimensions of each part of the Connector Conversion
Box are described below.
External cable
Terminal block
connected
cover opened
56 (2.21")
55 (2.17")
110 (4.34")
2)
3)
4)
8)
15)
13)
10)
11)
about
65 (2.56")*
1)
16)
6) 7)
5)
about 130 (5.12")*
12)
*Space required for connecting the cable
Unit: mm (inch)
Weight: about 0.5kg
No.
Name
Specifications
Connector for Handy
Connects a Handy GOT through an external
1)
GOT (42-pin,
connection cable.
female)
Supplies the power to the Handy GOT.
When this switch is set to ON, the power is supplied.
2)
Power switch
Turn off the power when attaching or detaching the
Handy GOT.
Lit in green: Power is correctly supplied. Not lit:
3)
POWER LED
Power is not supplied.
Hole for the panel
Used when mounting the panel. For M4 screw, depth
4)
installation
6mm
Packing attachment
5)
Used when mounting the panel.
chase
Used for fixing the Connector Conversion Box when
6)
Hook for DIN rail
mounting DIN rail (35mm).
Specifications
24VDC (+10% -15%)
13.7W or less (570mA/24VDC) (When including the consumption current of Handy GOT)
2.2W (90mA/24V) (When excluding the consumption current of Handy GOT)
25A or less (at max. load), 2ms
Within 5ms
Model name
GT1655HS-VTBD
Specifications
*1
GT16 Handy GOT User's Manual
No.
Name
Specifications
Hole for the screw
7)
Used for fixing on the board, etc. For M4 screw
installation
Connects the GT16H-CNB-42S, the 24VDC power
8)
Terminal block 1
supply of Handy GOT and the emergency stop switch
(ES-1 to 3) with M3 terminal screw and the cover.
Connects the operation switch of the Handy GOT
14)
(SW1 to 6), the grip switch (DSW-1, 2) and the
9)
Terminal block 2
keylock switch (KSW-1, 2) with M3 terminal and the
cover.
External connection
d e v i c e
10)
c o m m u n i c a t i o n
connector (RS-232:
Connects to the external connection device via a
D-Sub, 9-pin, male)
9)
GOT1000 series cable.
External connection
RS-422/485 connector and RS-232 connector cannot
d e v i c e
be used at the same time.
c o m m u n i c a t i o n
11)
connector (RS-422/
485: D-Sub, 9-pin,
female)
External connection
d e v i c e
Connects the external connection device via Ethernet
12)
c o m m u n i c a t i o n
with using a LAN cable.
connector (Ethernet:
RJ-45 module jack)
13)
Rotary switch (U)
Sets the ID number of GT16-CNB-42S.
Sets one ID number with using both rotary switches
14)
Rotary switch (L)
(U) and (L).
Enables the recognition function of ID number
I D n u m b e r v a l i d /
(ON=Valid, OFF=Invalid).
15)
i n v a l i d s e l e c t i o n
When connecting the external connection device with
switch
using 10) and 11), set OFF (invalid).
Hole for the flange
Used for fixing the flange when using the connector
16)
installation
conversion adapter.
4. Installation
The Connector Conversion Box can be installed on the panel face directly or on the DIN rail.
4.1 Mounting on the panel face
(When setting the connector for Handy GOT connection and the power supply switch on the panel surface)
1) Direct mounting on the panel face
Drill a mounting slot of the following size on the panel face.
Drill 4- 5±0.5 (0.2"±0.02")
77±0.5 (3.04"±0.02")
Panel cut area
4-R3 max (Panel opening)
61+1,-0 (2.41"+0.04",-0)
Unit: mm (inch)
(Panel opening)
3) Mounting on the panel face
Fit the Connector Conversion Box from the back side of the panel face, and fix it with four M4 screws (prepared by user).
In the Connector Conversion Box, thread of M4, 6mm (0.23") in depth is cut in each mounting hole. Prepare four M4 mounting screws separately while considering the
thickness of the panel face. (Tightening torque: 0.69 to 0.88 N•m)
Make sure that interfering objects are not located within 65mm (2.56") from the rear face so that the connector of a PLC cable is not hindered.
To wire the terminal block, keep a space of 25mm (0.98") or more on both sides of the Connector Conversion Box.
4.2 Mounting on the panel face (When installing the Connector Conversion Box on the panel surface)
1) Mounting on the panel face
Install the Connector Conversion Box on the panel face (mounting surface). Drill screw holes on the panel face as follows. Tighten the mounting screw with the specified
torque. Tightening screws too much may cause damage. (Tightening torque: 0.69 to 0.88 N•m)
43 (1.7") 6 (0.24")
M4 screw and nut
× 4 sets
(prepared by user)
4- 4.5 (0.18")
Unit: mm (inch)
4.3 Installed on the DIN rail
Install the Connector Conversion Box on the DIN rail
DIN rail depth
with using its DIN rail hook.
more than 10mm (0.4"inch)
(Applicable DIN rail DIN46277 (width: 35mm (1.37"))
The clearance between screws for install the DIN
rail should be 150mm (5.9") or less.
1) Pull out the hook for
2) Adapt the upper side of
3) Lock the hook for DIN rail
DIN rail.
the DIN rail installation
while forcing the product on
slot to the DIN rail.
the DIN rail.
When installing the DIN rail,
please fix the cables.
Otherwise, the hook for DIN
rail and other parts may be
damaged by the cable load.
2) Installation of the packing
Install the accessory packing to the packing attachment chase of the
Connector Conversion Box. Be sure to install the packing.
Elevation view
Packing attachment chase
25 (0.99")
65 (2.56")
25 (0.99")
Unit: mm (inch)
This manual confers no industrial property rights or any rights of any other
kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation
cannot be held responsible for any problems involving industrial property rights
which may occur as a result of using the contents noted in this manual.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be
the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the
Mitsubishi products; damage, secondary damage, accident compensation
caused by special factors unpredictable by Mitsubishi; damages to products
other than Mitsubishi products; and to other duties.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Advertisement

loading

This manual is also suitable for:

Gt16h-cnb-42s