Parameter; Analog Input Selection - Mitsubishi Electric 800 Series Instruction Manual

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

3

PARAMETER

3.1

Analog input selection

The analog terminal specification and the function to switch forward/reverse rotation by the input signal can be selected.
Pr.
73
Analog input selection
T000
*1
When Pr.73 = "6", the operation is the same as the one when the setting is "1". When Pr.73 = "16", the operation is the same as the one
when the setting is "11".
 Analog input specification selection
• To change the input specification, change the setting of Pr.73.
Pr.73 setting
0
1 (initial value), 6
10
11, 16
Initial
Name
value
1
Terminal 2 input
0 to 10 V
0 to 5 V
0 to 10 V
0 to 5 V
Setting range
The terminal 2 input specification (0 to 5 V, 0 to
*1
0, 1, 6
, 10, 11,
10 V) is selectable. Also the reversible operation
*1
16
setting is selectable.
Reversible operation
Disabled
Enabled
Description
27
PARAMETER
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e8te7

Table of Contents