Shutting down the server you are replacing

On the server that you are replacing:
Procedure
1. From the server console, issue the command: shutdown --ship --powerdown
Wait until the console displays Information: Server has shut down, and the
rear panel LEDs turn off. The PSU and server fans continue to run until you remove
the power cables from the PSU module. See the appropriate system component
section for more information.
2. Unplug the power cords from the power supplies.
3. Wait approximately 15 seconds, and then confirm the NVRAM status LED is off.
If the LED is flashing or fixed, press and hold the reset button for five seconds until
the LED starts flashing. The battery disables when you release the reset button.
4. Use the following rear panel figure and table to identify and label the cabling
placement on the existing server.
Hitachi NAS Platform 3080 and 3090 G2 Hardware Reference
Note: This specific powerdown command prepares the system for both
shipping, and potential long-term, post-replacement storage.
Appendix A: Server replacement procedures
Shutting down the server you are replacing
89