Date Published: May 2023 Rolec Services Ltd are the publishers of this document and own the rights to use the text, images and all technical content contained within. Content supplied by third parties / partner organisations remains the property of that organisation and is used by agreement with the supplier.
Product Support Contents Product Support Safety Safety Advice within this Manual Product Overview Product Features About ‘Smart’ Services About Load Balancing About Load Management About Demand Side Response About PEN Protection Security – Tamper Protection Product Specification Unpacking Standard Contents Options and Accessories Labelling Installation...
Rolec Services Ltd cannot accept any responsibility for improper installation or any problems arising from improper installation. NOTE: Damage to the equipment, connected systems or to property caused by improper installation are the responsibility of the installer.
Product Overview Product Overview The SECURICHARGE is the perfect wall-mounted EV chargepoint for workplaces and car parks with its heavy-duty and vandal-resistant features, making it the ideal solution for exposed locations. This future-proof OCPP compliant unit can offer a simple plug & charge or pay-to-charge solution via the EV driver’s smartphone and/or RFID card/fob through any chosen OCPP back-office management system.
Product Overview NOTE: The United Kingdom has introduced new regulations (SI 2021/1467) that apply to domestic and private EV chargepoints, and which aligns them with other ‘Smart’ appliances. The new regulations are, amongst other things, designed to balance demands for power and to deliver an efficient use of power across the country whilst maintaining a consistent and secure service to EV drivers, when and where they need it.
Rolec chargepoints are pre-configured to load balance with a 13A ‘buffer’. This means that whatever the property fuse may be, load balancing will start 13A before its maximum limit is reached.
NOTE: Where a Rolec Load Balancing Current Transformer (CT) has been installed and connected to a load balancing enabled Rolec chargepoint, it will reduce the supply of power to the vehicle where the combined demand of the property and vehicle would exceed the power available to the property as a whole.
Product Overview About PEN Protection The TruePEN system removes the need to install a dedicated earth for the chargepoint. In the event of a fault, the system will break all power cable connections between the chargepoint and the vehicle. A PEN fault is most commonly seen as either, an undervoltage or an overvoltage entering the chargepoint from the mains supply.
Product Specification Product Specification User Instructions External Antenna QR Code Socket ID Label RFID Sensor LED ‘Halo’ (on side) Status Indicator Charging Socket External RFID Antenna Sensor (on side) QR Code Socket ID Labels Charging Sockets Access Panel Figure 1 General Arrangement and Dimensions (Single and Double Socket Models) SecuriCharge Intelligent EV Charging Unit EVSM-V01-R3 Installation and Operation Manual Page 9 of 50...
Page 11
Product Specification EV Charge Controller for RFID Sensor socket 1(Front Layer) socket 2 (Rear Layer) RCBO (Socket 2) Smart Communications Module (Right-hand Side Panel) MID Meter (Socket 2) Socket 1 MID Meter (Socket 1) RCBO (Socket 1) Incoming Power Terminals (Single phase version shown) Figure 2 Internal Components - Typical Locations EVSM-V01-R3 Installation and Operation Manual...
Page 12
Product Specification Smart Link Connection Meter Connector 2x CT Connectors Status Indicator Power ‘IN’ ‘Halo’ Connector Connector to Power ‘OUT’ and N, E, L. Signal Connector to Socket or Cable L, N, E. Figure 3 EV Charge Controller GPRS Antenna Connection Connection to RFID Board...
Page 13
Product Specification Connection Charging Input Unit Product Type Output Supply Colour Code 1x 32A Black ROLEC0111B 1x Type 2 (IEC 62196) Up to 7.4kW (32A) Single Phase Grey ROLEC0111G charging socket per socket 230V AC (±10 %) Single 50/60Hz White ROLEC0111W Phase 1x 63A...
Page 14
Certification Markings – CE & UKCA Warranty 3 years Rolec Services Ltd are a registered manufacturer (WEE/AG3499TY) within the WEEE Recycling Scheme, allowing its products at the end of their life, to be processed by an appropriate local service provider.
Packaging is 100% recyclable where appropriate facilities exist. Standard Contents EV chargepoint Rolec ‘EV Connect’ Configuration Tag Monta QR Code Socket ID Label Installation and Operation Manual 1. Examine the package and make sure the contents have not been damaged in transit.
Labelling Labelling Observe any/all labels displayed on the equipment or inside the enclosure. Figure 5 Typical Product Rating and Serial Number Label Figure 7 Socket ID Label Figure 6 Configuration Tag (Back and Front) Figure 8 Instructions and RFID Label Figure 9 Typical Socket Type and power Rating Labels NOTES:...
Units using mobile networks require a suitable signal of 14 CSQ or better. Units using Wi-Fi connectivity require a strong, stable connection. Rolec cannot be held responsible or accountable in the event that a unit using a mobile network or Wi-Fi is installed in a location without adequate network signal.
Page 18
Installation 3. Determine where power and other cables (CT and Ethernet – if required) will enter the chargepoint enclosure. Discuss cable routing and cable entry into the enclosure with the end user. Plan the installation accordingly. Depending on the model of chargepoint, cables may enter through the bottom or back of the enclosure.
Installation Schematics INCOMING SUPPLY ACEQ0185 I ON 230V 50Hz O OFF I n 0.03A 10000 IEC/EN 61009-1 MAGNET 1 MAGNET 2 MAGNETIC MAGNETIC FIELD FIELD REED SWITCH 1 REED SWITCH 2 HEADER (FRONT VIEW) HEADER (FRONT VIEW) 230V 0.25-5(100)A 24 G 1000 imp/kWh 25 B...
Page 20
Installation Figure 11 SecuriCharge Intelligent EV Charging Unit – 2x up to 7.4kW Type 2 Socket SecuriCharge Intelligent EV Charging Unit EVSM-V01-R3 Installation and Operation Manual Page 19 of 50 May 2023...
Installation Install the Chargepoint IMPORTANT: All electrical work must be performed in accordance with the current legislation applicable in the geographical region of the installation. CAUTION: Equipment Damage – Sensitive Equipment If you will be performing insulation resistance tests on the power supply cables, it is advised to be done BEFORE connecting the power cable to the chargepoint.
Page 22
Installation 6. Carefully lift the chargepoint up to the mounting point and insert the fixings. Make sure the front facia is supported. The fixing points in the chargepoint enclosure are 5mm diameter. 7. Tighten the fixings gradually, making sure the chargepoint remains level. 8.
Installation Install Load Balancing NOTE: This manual assumes the installation of a single chargepoint. Whilst multiple chargepoints can be connected in a similar way, installers may wish to consider connecting/monitoring via third-party equipment. If connecting/monitoring via third-party equipment, make sure you are fully aware of the manufacturer’s instructions so that the device/system can be installed correctly and in conjunction with the chargepoint installation.
Installation Extend the CT Cable 1. If required, the CT cable may be extended up to a theoretical maximum of 100m. 2. To avoid interference and reduce the loss of signal, extension cables should be as short as possible. Extensions of 20m or less are recommended. 3.
Installation NOTES: Load Balancing 1. If extending the CT cable or adding Connections a solar monitoring CT, the cable colours will be those that you have chosen to use. 2. The lower two terminals on the CT Solar Monitoring connector may be used to attach a Connections CT used with a solar system.
4. Rolec Charge point ID label – This is a removable label attached to a red and black ‘tag’ that is supplied with the charge point and usually hung on one of the sockets or attached to the enclosure.
Rolec (01205 administration tasks can be performed between Rolec and Monta. Follow the automated call menu to be put through to the ‘Monta Onboarding Team’ or ask for the team if your call is answered by a human operator. Following the call you should receive an email link that will take you the Monta onboarding system.
Page 28
Configuration 1. Search the appropriate Apple or Google App store for Rolec EV Connect. Alternatively… Scan the QR code shown on the Configuration Tag to link to the configuration application. Or… Scan the QR code shown opposite or enter https://rolecevconnect.com into a web browser.
Product Overview The Rolec EV Connect Application is supplied by Rolec as a means of creating an initial connection between a smartphone or similar device and a Rolec manufactured EV charge point.
Page 30
Configuration These steps can be applied during the configuration processes described in the following pages when the application wants to use the phone camera to scan a QR code. 1. Make sure Bluetooth is enabled on the phone. 2. During the processes below, the EV Connect application will open or try to open the camera.
Configuration 6. Once the charge point is known, tap the MAC address and ID text to select it and move onto the password entry screen. 7. Enter the password (PW) exactly a shown on the QR code label. 8. Tap the Connect button to enter the configurations screen. Samsung Phone Users IMPORTANT: Samsung Phone Users In the following steps, if the charge point does NOT find ’Nearby Devices’, an on-screen...
2. The LED indicator on the charge point will flash BLUE when the chargepoint is ready. 3. Open the Rolec EV Connect application on the phone. 4. Read the privacy policy and accept the terms if you are happy to proceed.
Configuration Installer Registration 1. If using the application for the first time, you will need to register as an installer. 2. Tap the REGISTER text button. 3. Complete the fields presented on the next screens to add your details. First Name Last Name Company Name Company Registration Number...
Configuration Installer Projects 1. On the Installations – Recent Projects screen, tap the New button. 2. Select whether you are installing a charge point in a Home or a Commercial environment. This will influence some of the settings available during configuration.
Page 35
Configuration 5. Scan the removable QR Code label attached to the Configuration Tag. When the code has been read, the camera will close, and the charge point’s MAC address and Unique ID will be shown. 6. Tap the line of text showing the MAC address and ID.
Page 36
Configuration 10. To use the MONTA application, select Monta from the dropdown list. If a different application will be used, select the appropriate name from the list. The connection details of the chosen application will be automatically entered in the EV Connect application. NOTE: If an unlisted application is to be used, you must select OTHER, then refer to the application providers documentation for the connection details.
Page 37
Make sure you are fully aware of the provider’s terms and conditions and fees that may be associated with using the application/service. Your contract for these services will be with that provider and not with Rolec. IMPORTANT: INSTALLERS 1.
The LED indicator on the charge point will flash BLUE when the chargepoint is ready. Open the Rolec EV Connect application on the phone. Read the privacy policy and accept the terms if you are happy to proceed.
Page 39
Configuration 6. After a few seconds the connection process will be complete, and the Configuration screen will be displayed. 7. Enter the appropriate details into each of the fields of the form. Fields that have already been completed by the installer may not be accessible.
Make sure you are fully aware of the provider’s terms and conditions and fees that may be associated with using the application/service. Your contract for these services will be with that provider and not with Rolec. Monta Connections NOTE: These instructions were written using processes and screens shown by the Google Android smartphone system.
Configuration Commercial - Use a Charge Point with Monta Commercial site owners/operators who want to make their charge points visible to staff, will need to pair each charge point with a Monta Sticker that can be scanned by the drivers’ Monta Ap to enable a charge session. The owner/operator must first make sure all of their details are accurate and complete within the Monta portal.
3. Make sure the Charge points button is selected at the top of the screen. 4. Tap the Add a charge point button. 5. Follow the on-screen prompts to enter the charge point brand (Rolec) and model rge point rge poin then tap Continue.
Page 43
Configuration 10. Enter the charge point ID/Serial number. This number is on a removable label attached to the red and black charge point tag or may have been placed by the installer on the manual, the property fuse box, or the installation certificate.
Configuration Remove a Charge Point from Monta 1. Open the My charge points screen. 2. Tap the gear icon 3. Tap Delete charge point. A confirmation message will be displayed. 4. If you are sure the charge point can be deleted, tap the Delete button shown on the message.
Chargepoint Installation Completion Monta Labels The Monta ID Label located next to individual sockets or tethered cables can be used to enable charging by guests at your property, regardless of whether the driver is a Monta user. If enabled and configured in the owner’s Monta App, the guest simply scans the QR code on the label to connect to Monta where they can pay for and initiate a charge at their own cost.
Operation Operation As a ‘Smart’ product, this chargepoint can be operated and/or monitored by a wide range of web enabled devices. Alternatively, it may be operated manually via an RFID card/fob. 1. Refer to the status indicator guide to determine whether the chargepoint is available for use.
Operation NOTE: Default Hours and Randomised Delay Following the initiation of the charge session, UK regulations require chargepoints of this type to apply power for charging during the ‘default’ (off-peak) hours regardless of when the charge session was initially started. When the off-peak period is reached, power for charging will be applied after a randomised delay of up to 10 minutes.
Operation About Charging Cables and Sockets The points below apply to Rolec cables and will be similar for cables made by other manufacturers. Always follow the manufacturer's advice. 1. Charging cables should be fully uncoiled when in use. 2. Charging cables should not be stretched or place strain on the chargepoint or vehicle connections.
NOTE: In the event of a hardware issue, always contact your installer first. If damage has been sustained to communications devices and/or other ‘Smart’ components, it is recommended that an approved Rolec installer is called to perform the repair. Damage caused to the equipment by misuse, lack of maintenance, inappropriate maintenance or modification is not covered by the manufacturer warranty.
Maintenance 6. Do NOT allow charging cables to become contaminated with water (or other substances). Always store cables in accordance with the manufacturer’s instructions. NOTE: Rubber ‘dust’ caps that may be attached to cables are only suitable for short term protection, or protection whilst stored in an indoor environment. They are not designed to fully protect against water ingress.
Maintenance Suggested Inspection and Testing A record or inspection, testing and maintenance must be kept and may be required to support warranty claims. and 3 Quarter and 4 Quarter External Visual Inspection: External Visual Inspection: Check for physical damage. Check for physical damage. All warning labels present and All warning labels present and legible.
Page 52
Date Published: May 2023 Rolec Services Ltd are the publishers of this document and own the rights to use the text, images and all technical content contained within. Content supplied by third parties / partner organisations remains the property of that organisation and is used by agreement with the supplier.
Need help?
Do you have a question about the SECURICHARGE ROLEC0111 and is the answer not in the manual?
Questions and answers