Adjustment; Instruments Required For Adjustment And The Setup - JVC GY-HM600U Service Manual

Hd memory card camera recorder
Hide thumbs Also See for GY-HM600U:
Table of Contents

Advertisement

4.1

Instruments required for adjustment and the setup

4.1.1 Measuring instruments required for adjustment
Instrument
PC (Windows)
With an RS-232C compliant serial
communication port.
Color TV monitor
Supporting HD(1080/60i), with an
HDMI input.
Oscilloscope
100 MHz or higher (300 MHz is recom-
mended), calibrated instrument.
Signal generator
Output level change is possible.
(1kHz, 300Hz)
Digital volt meter
Calibrated instrument.
4.1.2 Jigs and tools required for adjustment
Adjustment software
Download from JS-NET
HM6xx_Adjust.exe
(.NET framework 4.0 required)
Light source
The halogen lamp of 3000K,
2600lx
4.1.3 Set up for adjustment
(1) Connect appropriate measuring instruments, jigs, and tools required for the adjustment item.
Light source
1-12 (No.HC047<Rev.001>)
SECTION 4

ADJUSTMENT

Condition
PC cable
QAM0099-002
YTU92001-018
INF adjustment lens
(Collimator)
YTU92001E
88.9% of reflectance
75
resistor for termination
Focus chart
Collimator
Instrument
Audio tester
Calibrated instrument.
Speaker
----------
DC power source
12V/1.7A or more, power source for light box.
AC adapter
Used as a power source for the unit.
(Accessory)
Thermometer, Color thermometer, Illuminometer
Focus chart
White chart
Color TV monitor
PC Cable
Condition
Oscilloscope
Video signal
To AUX
terminal