4. Loosen the piston cap anticlockwise and unscrew
it completely.
0 Insert the handle ends of a pair of linesman
pliers into the star-shaped handle of the
piston cap and carefully turn it anticlockwise.
5. Pull out the complete PISTON Service-Unit from
the FRC.
0 Pick up and dispose of any leaking or spilled
condensate in accordance with applicable
regional laws and requirements.
0 Dispose of the removed PISTON Service-Unit
properly (see section "14. Disposal" on
page 113).
6. Check the sealing surfaces in the FRC for
damage and dirt.
0 Remove any dirt.
0 If there is any damage, contact
BEKO TECHNOLOGIES Service (see section 
"1.1 Contact" on page 5).
7. Lightly lubricate the O-rings of the new
PISTON Service-Unit with the Vaseline supplied.
8. Insert the new PISTON Service-Unit in the FRC.