Elevator Pressure Relief and Console Wire Harness
Protection Kit
2024 Directional Drill
Model No. 132-4162
This product contains a chemical or chemicals known to the State of California to
Loose Parts
Use the chart below to verify that all parts have been shipped.
Description
Guard plate
Bolts (M10)
U-nut
Valve
Straight fitting
Valve bracket
Bolt (M6)
Flange nut
Large tee fitting
Small tee fitting
Long hydraulic hose
Short hydraulic hose
Installing the Wiring Harness
Guard
1. Move the machine to a level surface, turn off the
machine, and remove the key.
Note: Swing the operator platform full-out for easier
access; refer to the machine Operator's Manual.
2. Using the guard plate as a guide, drill a hole into the
frame; refer to
Figure
Note: Be careful not to drill into the wiring harness
wires.
© 2015—The Toro® Company
8111 Lyndale Avenue South
Bloomington, MN 55420
Proposition 65 Warning
cause cancer, birth defects, or reproductive harm.
1.
Register at www.Toro.com.
WARNING
CALIFORNIA
Qty.
1
2
Install the wiring harness guard.
2
1
2
1
Install the valve and bracket.
2
2
1
1
Install the fittings and route the hydraulic hoses.
1
1
1. Guard plate
2. U-nut
Form No. 3395-893 Rev A
Installation Instructions
Use
Figure 1
3. Bolt (M10)
4. Drill the hole here.
Original Instructions (EN)
All Rights Reserved *3395-893* A
Printed in the USA