OfficeServ 7100
TECHNICAL MANUAL
ALM
ALM
NO.
CODE
40
MJD09
41
MJD10
42
MJD11
43
MJD12
44
MJD13
45
MJD14
46
MJD15
47
MJD16
48
MJD17
49
MJD18
MMC: 852
ALARM
Bit Error Alarm
NTWRK Event
SPID Init Err
SPID Init Rec
LPBK Error
LPBK Recovery
BRI DL Unavail
BRI DL Recovered
RAM Error
T1 Restart
PART 2 APRIL 2007
DEFINITION
Alarm is activated when the when error
-6
rate exceeds 1x10
errors. Note: 1x10
is threshold for minor alarm, 1 x 10
threshold for major alarm errors on PRI
or BRI..
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
An Implausible event has occurred on
the PRI or BRI Network digital line.
Protocols do not match or subscriber ID
mismatch.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
The BRI received an error from the
network
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10),Channel(1 through 16)
The BRI has recovered from an error on
the network
Alarm Data = Cabinet, Slot Channel
C1,2
(S1 through 10),C (1 through 16)
Internal on demand loopback failed.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 24)
Internal on demand loopback test
passed.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 24)
A BRI data link is out of service.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 16)
A BRI data link is back in service.
Alarm Data = Cabinet, Slot Channel
(C1,2)
(S1 through 10), (C1 through 16)
An error has occurred in the T1/PRI or
BRI card RAM.
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
The T1 card has restarted
Alarm Data = Cabinet, Slot (C1,2) (S1
through 10)
PROGRAMMING
-6
-3
is