Installation
3

3.1 Before Installation

• Before installing, be sure the opening
measurements are su cient to receive the product
and that the appropriate electrical and plumbing
connections are present.
Water line pressure values psi kPa bar
Max Operating pressure :
Max pressure
for limting valve device
requirement :
Electrical requirements
Voltage
Frequency
Current
Power cord Lenght
• Installation should be performed by an Authorized
Installer with the necessary equipment. If electrical supply
does not meet the listed requirments above, an
Authorized Electrician should make all necessary changes.
Preparation of the location and
electrical installation at the place of
installation is the customer's
responsibility.
Plumbing: The refrigerator should
only be connected to the cold water
line.
WARNING
electrical connections of the product
must be carried out by the
AuthorizedService Agent. Manufac-
turer shall not be held liable for
damages that may arise from
procedures carried out by unautho-
rised persons.
WARNING
visually check if the product has any
defects on it. If so, do not have it
installed. Damaged products cause
risks for your safety.

3.2 Appropriate installation location

• Install the product at least 12"(30 cm) away from heat
sources such as cooktops, ovens, space heaters, radiators
and stoves at least 2" (5 cm) away from electrical ovens.
Product must not be subjected to direct sun light and
kept in humid places after installation.
• Do not place the product on the materials such as rugs
or carpets.
• Place the product on an even oor surface to prevent
wobbling.
• Do not install the product in places where the
temperature falls below 50F°/10ºC.
If two refrigerators are to be installed
side by side, there should be at least 4
cm 1 1/2"distance between them.
90
620
6.2
550
5.5
80
120V AC
60 Hz
15 A
7 ft.
: Installation and
: Prior to installation,
• Make sure that su cient room is provided around the
appliance to ensure free air circulation.
• For proper functionality, there should be a gap of at least 1
3/16" (30 mm) between the refrigerator and the rear wall.
To ensure this, attach the gray, rectangular bu ers, to be
installed on the top rear of the refrigerator.
These are shipped inside the crisper drawer in the Fresh
Food compartment.
1
2
3

3.3 Inset installations

• If the product will be installed within surrounding
cabinetry or in an alcove, be sure there is adequate air ow
around the product for proper functionality. This
refrigerator requires at least 2" from the top of the unit to
the ceiling or enclosure, 1/2" on each side and 1 3/16" in the
back.
• the spacer is shipped with the product
3.4 Electrical connection
• 120VAC, 60Hz, Dedicated 15Amp Circuit.
• GFCI outlets will provide added protection, but any
failure of the GFCI could cause food spoilage, which is
not covered by the manufacturer's warranty.
• Electrical connection must comply with national
regulations.
• Power cable plug must be within easy reach after
installation.
• Do not make connections via extension cables or
multi-plu gs.
7