Service And Inspection Intervals - Siemens SIMOTICS S-1FK2 Configuration Manual

Synchronous motors for sinamics s120
Hide thumbs Also See for SIMOTICS S-1FK2:
Table of Contents

Advertisement

Mechanical properties

3.12 Service and inspection intervals

3.12
Service and inspection intervals
Maintenance measures, inspection/maintenance times intervals
The maintenance intervals depend on the operating conditions.
NOTICE
Improper maintenance
Service and maintenance must only be performed by properly authorized qualified personnel.
Use original Siemens parts only.
Table 3-6
As required
When required or after 25000 operating hours
If required or after 25000 operating hours
Maintenance and repair of the motor can be performed by Siemens Service Centers throughout
the world.
Consult your Siemens representative if you require this service.
58
Maintenance measures after machine operating times or intervals
Machine operation times and intervals
Measure
Monitor and check the motor for unusual noise, vi‐
bration and changes
Check the radial shaft seal ring and replace it if worn.
For 1F☐2☐03 ... 1F☐2☐05 motors:
Replace motor.
For 1F☐2☐06 ... 1F☐2☐10 motors:
Replace engine bearing and encoder.
1FK2 Synchronous Motors for SINAMICS S120