ABB Ability Cassia X1000 Installation Manual

ABB Ability Cassia X1000 Installation Manual

Smart sensor bluetooth® gateway
Hide thumbs Also See for Ability Cassia X1000:

Advertisement

Quick Links

AB B M OT I O N S ER V I CE S
ABB Ability™ Smart Sensor Bluetooth
Gateway
Cassia X1000 installation manual
DOCUMENT ID
9AKK107046A4620
© Copyright 2021 ABB. All rights reserved.
REV.
L
DATE
August 2022
®
LANG.
PAGE
EN
1/29

Advertisement

Table of Contents
loading

Summary of Contents for ABB Ability Cassia X1000

  • Page 1 AB B M OT I O N S ER V I CE S ® ABB Ability™ Smart Sensor Bluetooth Gateway Cassia X1000 installation manual DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 1/29 © Copyright 2021 ABB. All rights reserved.
  • Page 2: Table Of Contents

    USB mobile dongle connection ................... 18 Firewall configuration ....................20 Verifying the configuration ..................21 2.10 Commissioning the gateway ................... 23 3 TROUBLESHOOTING ................. 25 DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 2/29 © Copyright 2021 ABB. All rights reserved.
  • Page 3: General

    AB B ABI LIT Y™ SM ART S ENSO R BLU ETOOTH ® G AT EWAY General The ABB Ability™ Smart Sensor gateway is used to upload the Smart Sensor data automatically to the Smart Sensor portal. The gateway needs to be configured for Internet access before it can start reading the Smart Sensors.
  • Page 4: Installation

    Smart Sensor Platform and all the existing subdomains must be whitelisted in the network for a successful communication and measurement report to the Portal. DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 4/29 © Copyright 2021 ABB. All rights reserved.
  • Page 5 Phillips head screwdriver and a drill (if needed) for wall mounting. Mounting is not mandatory, but it is recommended to secure the gateway somehow to its intended place. DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 5/29 © Copyright 2021 ABB. All rights reserved.
  • Page 6: Recommended Location

    If the gateway has trouble connecting to a specific Smart Sensor, it is recommended to rotate the gateway to point in that direction. DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 6/29 © Copyright 2021 ABB. All rights reserved.
  • Page 7: Gateway Configuration

    Default credentials are: Login: admin Password: admin Figure 2 Cassia (Firmware 1.4.3) Login Figure 3 Cassia (Firmware 2.1.0) Login DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 7/29 © Copyright 2021 ABB. All rights reserved.
  • Page 8 (1.4.3) and the new firmware (2.1.0), the latter having more information about the current state of the gateway. Figure 4 Cassia (Firmware 1.4.3) Status DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 8/29 © Copyright 2021 ABB. All rights reserved.
  • Page 9 AB B ABI LIT Y™ SM ART S ENSO R BLU ETOOTH ® G AT EWAY Figure 5 Cassia (Firmware 2.1.0) Status DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 9/29 © Copyright 2021 ABB. All rights reserved.
  • Page 10: Network Configuration - Firmware 1.4.3

    2.9 Verifying the configuration to check if the connection has been successfully set-up. DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 10/29 © Copyright 2021 ABB. All rights reserved.
  • Page 11: Network Configuration - Firmware 2.1.0

    2.9 Verify- ing the configuration to check if the connection has been successfully set-up. DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 11/29 © Copyright 2021 ABB. All rights reserved.
  • Page 12 AB B ABI LIT Y™ SM ART S ENSO R BLU ETOOTH ® G AT EWAY Figure 6 (Firmware 1.4.3) Basic page DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 12/29 © Copyright 2021 ABB. All rights reserved.
  • Page 13 AB B ABI LIT Y™ SM ART S ENSO R BLU ETOOTH ® G AT EWAY Figure 7 (Firmware 2.1.0) Basic page DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 13/29 © Copyright 2021 ABB. All rights reserved.
  • Page 14 If left on Auto mode the gateway could end up not properly connecting to the internet, needing to be power cycled to restore connection. Figure 8 4G only network mode DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 14/29 © Copyright 2021 ABB. All rights reserved.
  • Page 15: Poe Connection

    Connection Priority: Wired IP Allocation: DHCP or Static (in case the IP address is given) Press Apply at the bottom of the screen. DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 15/29 © Copyright 2021 ABB. All rights reserved.
  • Page 16: Lan/Ethernet Cable Connection

    Connection Priority: Wired IP Allocation: DHCP or Static (in case the IP address is given) Press Apply at the bottom of the screen. DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 16/29 © Copyright 2021 ABB. All rights reserved.
  • Page 17: Wifi Connection

    Press the reset button at the bottom of the gateway for 10 seconds to reset the gateway to factory default values, while the gateway is connected to power. DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 17/29 © Copyright 2021 ABB. All rights reserved.
  • Page 18: Usb Mobile Dongle Connection

    Reboot the gateway by removing the power supply for a few seconds and then reconnecting it. The Recommended Dongles for industrial environments are the following: MTCM2-L4G1-B03-KIT for Europe (LTE/CAT4) MTCM-LNA3-B03-KIT for US/Canada (LTE/CAT1) DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 18/29 © Copyright 2021 ABB. All rights reserved.
  • Page 19 Cellular Modem section. Please note that some countries may have regulations which may forbid the usage of certain types of hardware providers (e.g. Check if Huawei can be used in the US) DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 19/29 © Copyright 2021 ABB. All rights reserved.
  • Page 20: Firewall Configuration

    Firewall should allow communication between the gateway and Access Controller, and gateway and Smart Sensor platform respectively (see required ports in section 2.1 Prerequisites for Installation). DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 20/29 © Copyright 2021 ABB. All rights reserved.
  • Page 21: Verifying The Configuration

    Once the configuration is done, it can be verified from the status page. established to Access Controller the AC Online Time is shown. Figure 15 Gateway with FW 2.1.0 connected to gw.smartsensor.abb.com If the AC Online Time is not shown within few minutes:...
  • Page 22 Connection to Access Controller can be verified with Debug Tools in Other tab: To check the connection to the Access Controller, select NetCat, add Address gw.smartsensor.abb.com (or gw.smartsensor.abb.com.cn in case of China), Pro- tocol TCP, Timeout 2, Port 443 and press Start.
  • Page 23: Commissioning The Gateway

    Read the popup message, and make sure the gateway is in the required range. Tap OK, to confirm. Figure 17 Mobile APP Commission gateway option DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 23/29 © Copyright 2021 ABB. All rights reserved.
  • Page 24 Figure 18 Select gateway for commissioning • Finally, select a plant where you want to commission the gateway. Figure 19 Assign gateway to a plant DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 24/29 © Copyright 2021 ABB. All rights reserved.
  • Page 25: Troubleshooting

    Check the used network firewall settings. The necessary ports need to be open for outbound communication. Check if the Router Web Security under Other tab is toggled OFF (see below). Figure 20 Router Web Security option DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 25/29 © Copyright 2021 ABB. All rights reserved.
  • Page 26 The fields must be completed as shown below, then click Start. It will take ~10 seconds for the result to be shown. Figure 21 SpeedTest tool DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 26/29 © Copyright 2021 ABB. All rights reserved.
  • Page 27 The fields must be completed as shown below, then click Start. It will take ~10 seconds for the result to be shown. Figure 22 Traceroute tool DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 27/29 © Copyright 2021 ABB. All rights reserved.
  • Page 28 Bluetooth of the phone is active and wait for the list to populate. The APP shows both the signal quality and commissioning status. DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 28/29 © Copyright 2021 ABB. All rights reserved.
  • Page 29 Container tab. In case this happens, please contact Smart Sensor support. For more support, please contact Smart Sensor support: support.smartsensor@abb.com DOCUMENT ID REV. DATE LANG. PAGE 9AKK107046A4620 August 2022 29/29 © Copyright 2021 ABB. All rights reserved.

Table of Contents