and replace FSP-851, FSP-851T, and FSP-851R, which all supported FlashScan or CLIP mode. (Earlier versions named FSP-751 and
FSP-751T [both discontinued] also supported FlashScan or CLIP mode, but were not listed for use in ducts. Earlier models named SDX-
551, SDX-751, and SDX-551TH were CLIP mode only.
FST-951/FST-951-IV Intelligent thermistor sensing circuit for fast response. Designed to provide open area protection with 50 foot
spacing capability. A fixed temperature sensor with 135°F (57.2°C) fixed temperature alarm. The FST-951R/FST-951R-IV incorporates
a thermal rate of rise of 15°F (8.3°C). The FST-951H/FST-951H-IV is a high temperature sensor with 190°F (87.8°C) fixed temperature
alarm. Basic models support FlashScan mode only; models ending in -IV support FlashScan and CLIP mode.These models update and
replace FST-851 , FST-851R, and FST-851H, which all supported FlashScan or CLIP mode. (Earlier versions named FST-751 and FST-
751R [both discontinued] also supported FlashScan or CLIP mode. Earlier models named FDX-551, and FDX-551R were CLIP mode
only.)
FSD-751P Photoelectric Duct Detector. The FSD-751RP includes an alarm relay. All models support FlashScan or CLIP mode.
FSD-751PL Low-flow Photoelectric Duct Detector, with extended speed range of 100–4000 FPM (0.5 m/s to 20.3 m/s). FSD-751RPL
adds a relay. Both models support FlashScan or CLIP mode.
DNR/W Innovairflex intelligent, non-relay, low-flow photoelectric duct detector housing. Low Flow refers to the air velocity rating of
100 to 4,000 feet per minute (0.5 to 20.32 m/sec). Use with FSP-851R/FSP-951/FSP-951-IVphotoelectric smoke detector. Accommo-
dates the installation of the FRM-1 addressable relay module. The DNRW is the same as the DNR with a watertight housing.
FSH-751 (HARSH™) A special smoke detector that provides early warning smoke detection in hostile environments where traditional
smoke detectors are not practical. Supports FlashScan or CLIP mode. (An earlier model named HPX-751 was CLIP mode only.)
FSL-751 VIEW® An advanced intelligent photoelectric detector that uses a laser diode, special optics, and signal processing to obtain
extremely high sensitivity. Supports FlashScan and CLIP mode; compatible with AFP-300/AFP-400, NFS-640, NFS2-640, NFS-320
and NFS-3030/NFS2-3030 only. LPX-751L is compatible with AFP-200 and AM2020/AFP1010; CLIP mode only. (An earlier version
named LPX-751 was CLIP mode only and compatible with AFP-300/AFP-400.)
FSA-5000 Intelligent FAAST
Compatible with NFS-320, NFS-320SYS, NFS2-640, and NFS2-3030 only. Addressed using PipeIQ® software.
FSA-8000 Intelligent FAAST
CLIP mode. (An earlier model was CLIP mode only). Compatible with NFS-320, NFS-320SYS, NFS2-640, and NFS2-3030 only.
Addressed using PipeIQ® software.
FSA-20000 Intelligent FAAST
can and CLIP mode. Compatible with NFS-320, NFS-320SYS, NFS2-640, and NFS2-3030 only. Addressed using PipeIQ® software.
FSA-20000P Intelligent FAAST
for higher resolution of location. Supports FlashScan and CLIP mode. Compatible with NFS-320, NFS-320SYS, NFS2-640, and NFS2-
3030 only. Addressed using PipeIQ® software.
1.6.9 Addressable Manual Pull Stations
The NBG-12LX is a dual-action pull station that, when activated, provides an addressable identification and its location to the control
panel. An addressable monitor module is mounted inside the pull station to facilitate servicing and replacement. Supports FlashScan or
CLIP mode. An earlier model named BGX-101L was CLIP mode only.
The NBG-12LXSP is a Spanish/English labeled version; NBG-12LXP is a Portuguese-labeled version. Both support FlashScan or CLIP
mode.
1.6.10 Wireless Interface
FWSG: The Wireless Gateway acts as a bridge between a group of wireless fire devices, and a FlashScan SLC loop on NFS-320, NFS-
320SYS, NFS2-640, and NFS2-3030 (operating with firmware version 22.x or higher). The Gateway can be powered by the SLC loop or
by an external 24VDC UL listed power supply. Available wireless devices include a photo detector, an Acclimate detector, a fixed-tem-
perature heat detector, a rate-of-rise heat detector, a monitor module, and a relay module. For details about wireless devices, system
setup, and operation, see the SWIFT® Smart Wireless Integrated Technology Instruction Manual.
NOTE: Wireless option is not suitable for ULC applications.
1.6.11 ACPS-610 Addressable Charger/Power Supply
The ACPS-610 is an addressable power supply and battery charger with 24 VDC outputs. It operates in FlashScan or CLIP mode and has
built-in strobe synchronization. Its four outputs may be independently configured to drive Notification Appliance Circuits (NACs) or to
provide auxiliary power.
1.6.12 ACPS-2406 Addressable Charger/Power Supply
The ACPS-2406 is an auxiliary power supply and battery charger. Each of its four Notification Appliance Circuits (NAC) is individually
addressable, eliminating the need for control modules. In addition, each circuit can provide notification appliance synchronization.
FlashScan and CLIP capable. This product has been discontinued.
1.6.13 AMPS-24 Addressable Power Supply
The AMPS-24 is a primary power supply and battery charger. Depending on its configuration, it can occupy either one or four addresses
on an SLC. FlashScan capable.
14
®
XS aspiration smoke detector. Covers 5,000 square feet through one pipe. Supports FlashScan mode.
®
XM aspiration smoke detector. Covers 8,000 square feet through one pipe. Supports FlashScan and
®
XT aspiration smoke detector. Covers 28,800 square feet through one to four pipes. Supports FlashS-
®
XT PRO aspiration smoke detector. Covers 28,800 square feet through one to four addressable pipes