Sign In
Upload
Manuals
Brands
Honeywell Manuals
Control Panel
NOTIFIER NFW-100X
Honeywell NOTIFIER NFW-100X Manuals
Manuals and User Guides for Honeywell NOTIFIER NFW-100X. We have
3
Honeywell NOTIFIER NFW-100X manuals available for free PDF download: Manual, Operating Instructions Manual
Honeywell NOTIFIER NFW-100X Manual (164 pages)
Addressable Fire Alarm Control Panel
Brand:
Honeywell
| Category:
Control Panel
| Size: 2.8 MB
Table of Contents
Table of Contents
5
Section 1: Product Description
13
Features and Options
13
Specifications
14
Controls and Indicators
16
Components
16
1: Intelligent Addressable Detectors
17
2: Intelligent Addressable Modules
17
3: Addressable Device Accessories
17
End-Of-Line Resistor Assembly
17
Power Supervision Relay
17
EOL-C(R/W) Mounting Plate
17
Optional Modules
17
Accessories
18
1: FS-Tools Programming Utility
18
2: Dress Panel
18
3: Trim Ring
18
4: Battery Box
18
Nfs-Lbb
18
5: Battery Charger
18
6: Nfc-50/100
19
7: Nfc-Fft
19
8: FWSG Wireless Gateway
19
9: ANN-BUS Annunciators/Modules
19
Guidelines
19
N-ANN-80/N-ANN-100 Remote Fire Annunciators
19
N-ANN-S/PG Serial/Parallel Interface Module
19
N-ANN-I/O LED Driver Module
19
N-ANN-LED Annunciator Module
20
N-ANN-RLY Annunciator Module
20
Getting Started
20
Telephone Requirements and Warnings
20
1: Telephone Circuitry
20
2: Telephone Company Rights and Warnings
21
Section 2: Installation
22
Mounting the Backbox
22
Power
25
1: AC Power and Earth Ground Connection
25
2: Battery Power
25
3: Special Application DC Power Output Connection
26
Relays
26
Notification Appliance Circuits
26
1: Class B NAC Wiring
27
2: Class a NAC Wiring
27
Remote Synchronization Output
28
UL Power-Limited Wiring Requirements
29
IPOTS-COM Communicator
30
Wiring
30
Dip Switches
31
Optional Module Installation
31
1: Cell-Cab-N/Cell-Mod
31
Installation
31
Wiring
31
2: PWRMOD24 NAC Expander
31
Installation and Wiring
31
3: 4XTM Transmitter Module Installation
31
4: ANN-BUS Annunciators/Modules
33
ANN-BUS Wiring
33
ANN-BUS Device Addressing
36
N-ANN-80 Remote Fire Annunciator
36
N-ANN-100 Remote Fire Annunciator
38
N-ANN-S/PG Serial/Parallel Interface Module
39
N-ANN-I/O LED Driver Module
41
N-ANN-LED Annunciator Module
43
N-ANN-RLY Annunciator Module
45
5: Printer
46
Printer Configuration
46
6: NFC-FFT Firefighter Telephone
47
7: FWSG Wireless Gateway
47
Automatic Audio Panel Control
47
Section 3: Programming
49
Programming Data Entry
49
User Programming
50
Initial Power-Up
51
Programming Screens Description
51
Programming and Passwords
51
Master Programming Level
52
1=Autoprogram
52
2=Point Program
53
Detector Programming
53
Module Programming
60
3=Zone Setup
68
Enable
68
Disable
68
Special Purpose Zone
69
Zones Installed
69
Zones Enabled
69
Zones Disabled
69
Zone Type
70
Zones Available
70
Zone Message
70
4: Loop Setup
71
Class
71
Loop Protocol
71
Device Addressing
71
5: System Setup
71
Function Keys
72
Banner
72
Time-Date
73
Timers
74
NAC (Notification Appliance Circuit)
75
Relays
78
Canadian Option
79
Waterflow Silenceable
79
MNS Override
79
Auxiliary Power
79
Trouble Reminder
80
Language
80
Charger Enable
80
4XTM Supervision
80
Remote Sync Enable
80
6: History
80
View Events
81
Erase History
81
7: Communicator
81
Communicator Installed
81
POTS Settings
81
IP Settings
82
Primary and Secondary Communication Paths
83
Trouble Report Limit (Dialer Runaway Prevention)
86
Report Style
87
Event Codes
87
8: Annunciators
90
ANN-BUS Setup
90
ANN-BUS Options
97
9: Password Change
99
Invalid Password
99
10: Clear Program
100
11: Program Check
100
Maintenance Programming Level
101
1: Disable Point
101
2=History
102
3: Program Check
102
4: Walktest
103
5: System
104
6: Zone Setup
104
Section 4: Operating Instructions
106
Panel Control Buttons
106
1: Acknowledge
106
2: Alarm Silence
106
3: Drill/Hold 2 Sec
106
4: Reset
106
5: Function Keys F1-F4
106
LED Indicators
106
Normal Operation
107
Trouble Operation
107
Alarm Operation
108
CO Alarm Operation
109
Supervisory Operation
109
Process Monitor Operation
110
Hazard/Tornado Condition Operation
110
Medical Alert Condition Operation
110
Mass Notification Operation
111
NAC Operation
111
Programmed Zone Operation
111
Disable/Enable Operation
111
Waterflow Circuits Operation
111
Detector Functions
111
Time Functions: Real-Time Clock
112
Synchronized NAC Operation
112
Coded Operation
112
Presignal
112
Positive Alarm Sequence
112
Special System Timers
113
1: Silence Inhibit Timer
113
2: Autosilence Timer
113
3: Trouble Reminder
113
4: Waterflow Retard Timer
113
5: Alarm Verification (None or One Minute)
113
6: Control Module Delay Timer
114
Walktest
114
Read Status
114
1=System Point
114
2=Zones
115
3: Trouble Reminder
116
4: Timers
116
5: Nacs
116
6: Relays
116
7: Program Check
116
8: History
117
9: Annunciators
117
10: Communicator
117
11: Print
118
Chamber Value
119
Drift Compensation
119
Maintenance Alert
119
12: Time-Date
120
13: Battery Charger
120
14: 4XTM Supervision
120
15: Remote Sync
120
Section 5: Central Station Communications - POTS Transmission
121
Transmittal Priorities
121
Section 6: FS-Tools Upload/Download
123
FS-Tools Upload/Download
123
Transferring a Program
123
1: Security Features
124
Secret Code Verification
124
Time-Out at Control Panel
124
Error Checking
124
Central Station Data Protection
124
Section 7: USB Upload/Download
125
USB Upload/Download
125
Section 8: Firmware Upgrade
127
Firmware Upgrade
127
Section 9: Power Supply Calculations
128
Overview
128
Calculating the AC Branch Circuit
128
Calculating the System Current Load
128
2: How to Calculate System Current Load
128
Calculating the Battery Size
130
1: NFPA Battery Requirements
130
2: Selecting and Locating Batteries
130
Appendix A: Software Zones
131
A.1: Correlations
131
Appendix B: Default Programming
137
Appendix C: NFPA Standard-Specific Requirements
138
C.1: MBT-1 Municipal Box Trip - Silenceable
141
Appendix D: Wire Requirements
142
D.1: NAC Wiring
143
Appendix E: HVAC Control
144
E.1: Control Module Operation
144
E.1.1: Hvac Shutdown
144
E.2: Monitor Module Operation
145
E.2.1: Hvac Restart
145
E.2.2: Hvac Ovrride
145
Appendix F: Ademco Contact ID Format Event Code Descriptions
146
F.1: Transmission Format between DACT and Receiver
146
F.2: Ademco Contact ID Typical Printout
146
Appendix G: Central Station Points
151
Appendix H: NFPA Requirements
153
Appendix I: Open/Short/Ground Trip Values
154
Index
155
Advertisement
Honeywell NOTIFIER NFW-100X Manual (166 pages)
Addressable Fire Alarm Control Panel
Brand:
Honeywell
| Category:
Control Panel
| Size: 2.77 MB
Honeywell NOTIFIER NFW-100X Operating Instructions Manual (20 pages)
Addressable Fire Alarm Control Panel
Brand:
Honeywell
| Category:
Control Panel
| Size: 0.16 MB
Table of Contents
Installation Precautions
3
FCC Warning
3
Section 4: Operating Instructions
4
Panel Control Buttons
4
Led Indicators
4
Normal Operation
5
Trouble Operation
5
Alarm Operation
6
CO Alarm Operation
7
Supervisory Operation
7
Process Monitor Operation
8
Hazard/Tornado Condition Operation
8
Medical Alert Condition Operation
8
Special System Timers
11
Advertisement
Advertisement
Related Products
Honeywell NOTIFIER NFW-50X
Honeywell NOTIFIER NFW-100XI
Honeywell Notifier NFW-50XI
Honeywell nfs2-3030
Honeywell Notifier NFS-320
Honeywell Notifier NFS-320SYS
Honeywell Notifier NFS-320SYS/E
Honeywell NOTIFIER NFS-640
Honeywell Notifier NFS-320/E/C
Honeywell NOTIFIER NCA-2
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL