Chapter 3 Appendix
Error Message
B272
PCI Slot 2 - PCIe Link Speed
Error
C000
The error occurred during
fan sensor reading.
C010
The error occurred during
temperature sensor reading
C011
System Temperature out of
the range.
C020
The error occurred during
voltage sensor reading.
C021
System Voltage out of the
range.
C040
SROM data read error
C041
SROM data checksum bad
C061
1st SMBus device Error
detected.
C062
2nd SMBus device Error
detected.
C063
3rd SMBus device Error
detected.
C064
4th SMBus device Error
detected.
C065
5th SMBus device Error
detected.
C066
6th SMBus device Error
detected.
C067
7th SMBus device Error
detected.
C068
8th SMBus device Error
detected.
C101
BMC Memory Test
Failed..
C102
BMC Firmware Code
Area CRC check
Failed.
C103
BMC core hardware failure.
BMC IBF or OBF check failed. An error was detected while
C104
C105
BMC SEL area full.
110
Cause
PCIe bus speed error was detected
on PCI slot 2.
An error was detected while reading
fan sensor.
An error was detected while reading
temperature sensor.
A temperature abnormality was
detected.
An error was detected while reading
voltage sensor.
A system voltage abnormality was
detected.
An error was detected while reading
FRU data.
A checksum error was detected
while reading FRU data.
An error was detected on 1st SM
Bus.
An error was detected on 2nd SM
Bus.
An error was detected on 3rd SM
Bus.
An error was detected on 4th SM
Bus.
An error was detected on 5th SM
Bus.
An error was detected on 6th SM
Bus.
An error was detected on 7th SM
Bus.
An error was detected on 8th SM
Bus.
An error was detected on BMC.
accessing BMC.
There is not enough space to store
the system event log.
Express5800/E120d-M Maintenance Guide
1. POST Error Message
Solution
Contact your sales representative.
It is possible that an ambient temperature of
installation site is high, or a fan has failed or
is clogged. Contact your sales
representative.
Contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Start up Offline Tools (Chapter 1, 7. Offline
Tools) and delete the event logs.