Fujitsu PRIMEHPC FX1000 Operating Manual page 94

Supercomputer
Hide thumbs Also See for PRIMEHPC FX1000:
Table of Contents

Advertisement

Appendix B CPU-MEM-RAS Driver Messages
[ERR.] xos RAS 0021 - internal information GPR, SP register error detected. esr=DATA1
ERR0STATUS=DATA2
Meaning
A parity error was detected in GPR or Stackpointer.
DATA1: ESR register value
DATA2: Error status register value
Action
Collect investigation data according to
contact Fujitsu Support with the collected data together with the output message.
[ERR.] xos RAS 0022 - internal information FP&SIMD, vector, predicate register error detected.
esr=DATA1 ERR0STATUS=DATA2
Meaning
A parity error was detected in the FP&SIMD register.
DATA1: ESR register value
DATA2: Error status register value
Action
Collect investigation data according to
contact Fujitsu Support with the collected data together with the output message.
[ERR.] xos RAS 0023 - internal information Invalid error code or type detected when SError
occurred. esr=DATA1 ERR0STATUS=DATA2
Meaning
SError occurred.
The error code or error type is invalid.
DATA1: ESR register value
DATA2: Error status register value
Action
Collect investigation data according to
contact Fujitsu Support with the collected data together with the output message.
[ERR.] xos RAS 0024 - internal information MARKED_UE detected. esr=DATA1
ERR0STATUS=DATA2
Meaning
Error-marked data was used.
DATA1: ESR register value
DATA2: Error status register value
Action
Collect investigation data according to
contact Fujitsu Support with the collected data together with the output message.
[ERR.] xos RAS 0025 - internal information Uncorrectable Address Error(Load, Instruction
access) detected. esr=DATA1 ERR0STATUS=DATA2
Meaning
An error due to incorrect memory access (Load, Instruction access) was detected.
DATA1: ESR register value
DATA2: Error status register value
Action
"5.3.1 Collecting Information for Maintenance
"5.3.1 Collecting Information for Maintenance
"5.3.1 Collecting Information for Maintenance
"5.3.1 Collecting Information for Maintenance
76
Purposes," and then
Purposes," and then
Purposes," and then
Purposes," and then
C120-0089-03EN

Advertisement

Table of Contents
loading

Table of Contents