Table 16.
Parts and Tools for fixing RRH_1 Sector Wall Type (Standard & Side Installation)
Category
Parts
Recommended Torque Value
Working Tools
2
Figure 46.

Fixing RRH_1 Sector Wall Type (Standard Installation)

RFV01U-D1A Installation Manual v2.0
Copyright © 2017, All Rights Reserved.
Description
M10 × 35L Hex. Bolt (washer assembly,
attached to the unit bracket)
M10 Hex. Bolt
Torque Wrench (100~400 lbf·in), Torque Wrench Spanner head (apply Hex.
Head: 17 mm), Spanner (17 mm)
Hang the unit bracket hook of RRH side on the mounting bracket_front hook's
groove and fix it using fasteners.
Chapter 2 Installing System
Unit Bracket Hook
Mounting Bracket_Front
Hook Groove
M10 Hex. Bolt
(washer assembly)
Confidential
1 EA
217 lbfin (250 kgf·cm)