Table 17: Cleaning Parameters Wet Cleaning Of Turbine And Nozzle Ring - ABB A170-M62 Operation Manual

Hide thumbs Also See for A170-M62:
Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-M axial
6 Periodic maintenance / 6.5 Cleaning turbine and nozzle ring
¡
The exhaust gas temperature downstream of the turbocharger drops drastically during
cleaning (typical turbocharger outlet temperatures during cleaning: 60...180°C).
¡
If there is no drainage of the gas outlet casing, the turbocharger speed and/or the gas
inlet temperature must be monitored during the cleaning process. If the load is too low,
water can collect in the gas outlet casing. Indicators for this are a sudden severe drop in
the turbocharger speed or a very large increase in the gas inlet temperature. In such
cases, the cleaning operations must be stopped and the cleaning cycle restarted with re-
duced water pressure or higher engine load.
Cleaning parameters for wet cleaning of turbine and nozzle ring
Product
Maximum temperature
when starting cleaning
T
A170-M
A175-M
Table 17: Cleaning parameters Wet cleaning of turbine and nozzle ring
© Copyright 2019 ABB. All rights reserved.
Injection time
[°C]
TI
430
Water volume flow per turbocharger
[min]
i
10
HZTL4033_EN
at p
= 3 bar
Water
V
[dm³/min]
W
30
41
Rev.D