Fig. 8: Loosening The Clamping Nut - ABB A170-M62 Operation Manual

Hide thumbs Also See for A170-M62:
Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-M axial
2 Removal and installation / 2.2 Removing the turbocharger
2.2.1
Loosening the clamping nut
CAUTION
Incorrect procedure can make loosening impossible
If individual pressure screws are fully relieved, the pressure screws can be-
come compressed, making it impossible to loosen them.
Comply with the following steps for loosening the pressure screws.
u
CAUTION
Do not clean pressure screws
The pressure screws are equipped with a permanent sliding layer that must
not be removed. In case of non-compliance, it cannot be ensured that the
necessary tension force is reached.
Do not clean pressure screws.
u
Do not lubricate pressure screws.
u
If a screw jams, the previously loosened screw must be tightened again a little.
Fig. 8: Loosening the clamping nut
1. Working in a circle, break loose each pressure screw (≤ 20°).
2. Working in a circle, loosen each pressure screw by 45° in 4 rounds.
3. In 1 to 5 rounds, loosen each pressure screw by 90° in circular order until all pressure
screws have been relieved.
Unscrew and remove the clamping nut by hand.
u
© Copyright 2019 ABB. All rights reserved.