Mitsubishi Electric MELSECQ Series User Manual page 98

Multichannel high-speed counter module
Hide thumbs Also See for MELSECQ Series:
Table of Contents

Advertisement

6
UTILITY PACKAGE (GX Configurator-CT)
6
- 20
Downloaded from
ManualsNet.com
[Explanation of items]
(1) Items
Setting item
Current value : Monitors the I/O signal states and present buffer memory values.
Setting value : Enter or select values to be written into the buffer memory for test
(2) Command buttons
/
Remark
The following describes an example when [Execute test] settings are changed as
follows:
• Period setting: 3000 ms
• Periodic pulse counter start command (Y05): ON
(1) Click [Setting value] field for [CH
(2) After inputting a period [unit: 10 ms] (input "300" in case of the above
example), press the
At this moment, the input value has not yet been written to the QD63P6.
(3) Select [ON] in [Setting item] field of [CH
command (Y05)].
(4) Select the [Setting value] fields input in (1) to (3) while pressing the
key. Dragging operation using the mouse can also select multiple items.
(5) Click the
After the writing, the written value is updated in the [Current value] field.
6.6 Monitoring/Test
6.6.1 Monitoring/Test
search engine
: Displays I/O signals and buffer memory names.
operation.
Displays the current value of the item selected. (This is
used to check the text that cannot be displayed in the
current value field. However, in this utility package, all
items can be displayed in the display fields).
Creates a file containing the screen data in text file
format.
Selects whether or not to monitor current values.
Performs a test on the selected items. To select more
than one item, select them while holding down the
key.
Ctrl
Closes the screen that is currently open and returns to
the previous screen.
key.
Enter
button for writing.
Period setting] to select it.
Periodic pulse counter start
Ctrl

Advertisement