Siemens LITHOSTAR Multiline Installation Instructions Manual
Siemens LITHOSTAR Multiline Installation Instructions Manual

Siemens LITHOSTAR Multiline Installation Instructions Manual

Hide thumbs Also See for LITHOSTAR Multiline:
Table of Contents

Advertisement

Quick Links

LITHOSTAR Multiline
System
Installation Instructions
for Subcontractors and Siemens Technicians
Print No.: RXL2-120.812.01.02.02
Replaces: RXL2-120.812.01.01.02
SP
© Siemens AG 2004
The reproduction, transmission or
use of this document or its contents
is not permitted without express
written authority. Offenders will be
liable for damages. All rights,
including rights created by patent
grant or registration of a utility
model
_or_ design,_are_
reserved.
English
Doc. Gen. Date: 10.04

Advertisement

Table of Contents
loading

Summary of Contents for Siemens LITHOSTAR Multiline

  • Page 1 LITHOSTAR Multiline System Installation Instructions for Subcontractors and Siemens Technicians © Siemens AG 2004 The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights,...
  • Page 2 Assemblers and other persons who are not employed by or otherwise directly affiliated with or autho- rized by Siemens or one of its affiliates are directed to contact one of the local offices of Siemens or one of its affiliates before attempting installation or service procedures.
  • Page 3: Table Of Contents

    Connections and cable locations in the A12 electronics cabinet ... . 3 - 2 Siemens AG RXL2-120.812.01 Page 3 of 4 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24...
  • Page 4 Adapting the Other Accessories ......5 - 2 6 ______ Changes to previous version _____________________________________6 - 1 LITHOSTAR Multiline RXL2-120.812.01...
  • Page 5: Items Included In The Shipment

    • All texts referring to adjustments or installation steps marked with symbol” ” have to be confirmed by the subcontractor or the Siemens engineer in the installation protocol (register 3 of logbook). Replacement of damaged or Lost Screws •...
  • Page 6: Safety Notes

    Materials • Loctite 221 20 48 874 RV090 • Oil for high voltage transformer H1 99 00 952 for refilling only, if required LITHOSTAR Multiline RXL2-120.812.01 Page 2 of 4 Siemens AG System Rev. 02 10.04 CS PS 24 Medical Solutions...
  • Page 7: Component Overview

    Monitor I + II Monitor (Option) System controller Operating Polydoros LX system unit Water Multispot prepara- Power or DICOM tion supply Connect (Options) Siemens AG RXL2-120.812.01 Page 3 of 4 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 8 Monitor I + II System Monitor (Option) controller Operating Polydoros SX system unit Water Multispot prepara- Power or DICOM tion supply Connect (Options) LITHOSTAR Multiline RXL2-120.812.01 Page 4 of 4 Siemens AG System Rev. 02 10.04 CS PS 24 Medical Solutions...
  • Page 9: Preparation

    Check the cable feed-throughs for the Patient monitor for usability. • Make sure that there is sufficient space for a Patient monitor. Siemens AG RXL2-120.812.01 Page 1 of 14 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 10: Polydoros Lx

    If necessary, knock out the cable inlet in the generator cabinet for interconnections with the adjacent cabinet. Install the edge protection strip (service package). • Mount the generator in place by inserting the 4 hex bolts into the Liebig screw anchors. LITHOSTAR Multiline RXL2-120.812.01 Page 2 of 14 Siemens AG System Rev.
  • Page 11: Installing And Connecting The High Voltage Charger

    Connect the power line cable at N12 (1 on L1, 2 on N and ge/gn on PE). • Plug in the cable from the N12, K108 to the charger controller on the charger. Siemens AG RXL2-120.812.01 Page 3 of 14 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 12: Installing And Connecting The Cooling Unit

    CAUTION When lowering the unit, the cable harnesses must not be dam- aged. • Move the unit to its installation location and place it next to the mounting plate. LITHOSTAR Multiline RXL2-120.812.01 Page 4 of 14 Siemens AG System Rev. 02 10.04...
  • Page 13 - blue for the shock wave cabinet - green for the control cabinet - yellow for the generator The correspondingly color-coded target connections are located in the cabinets. Siemens AG RXL2-120.812.01 Page 5 of 14 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 14 Do not block the movement of the energy chain. CAUTION Excess cable lengths may not be stored in the cabinets. • Remove the transport safety bracket from the I.I. collision protection. LITHOSTAR Multiline RXL2-120.812.01 Page 6 of 14 Siemens AG System Rev.
  • Page 15: Installing The Covers

    /Fig. 11); for this, the mounting brackets must be installed on the inside of the frame. • Attach the cover (K/Fig. 11) for the cable routing using two paneling screws. Siemens AG RXL2-120.812.01 Page 7 of 14 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 16 Attach the paneling to the underside of the shock head support (A/Fig.14). • In the front section of the base frame (B/Fig. 14), use black plastic plugs to seal the two holes for mounting the transport carriage. LITHOSTAR Multiline RXL2-120.812.01 Page 8 of 14 Siemens AG System Rev.
  • Page 17: Installing The Components For The System Controller

    Connect the tableside control with the holder to the unit. • Connect the unit footswitch (optional) on the right in back of the unit. Siemens AG RXL2-120.812.01 Page 9 of 14 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 18: Back Panel Of The Pc

    Positioning/Connecting DICOM Connect (Option) • Perform installation and startup according to the manual RXL2-120.814.02.. NOTICE DICOM can be built into the LITHOSTAR Multiline only if no MULTISPOT is installed. LITHOSTAR Multiline RXL2-120.812.01 Page 10 of 14...
  • Page 19: Positioning/Connecting The Multiformat Camera (Option)

    • Connect the cable routed from power supply unit at the Diamentor. • Position the Diamentor on the console desk. Siemens AG RXL2-120.812.01 Page 11 of 14 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 20: Installing The Tv Camera On The 23" I.i

    Check the temperature indicators of the image intensifier according to the installation instructions regarding temperature checks with SIRECON units and OPTILIX tubes in RXD0-000.038.01... The results of the evaluation are recorded in the image quality protocol (IQC) during start-up. LITHOSTAR Multiline RXL2-120.812.01 Page 12 of 14 Siemens AG System Rev.
  • Page 21: Installing The Collimator

    Reattach the cover to the collimator. • Plug the two connectors together and fix the cable with the cable ties (2/Fig. 20). Siemens AG RXL2-120.812.01 Page 13 of 14 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 22 • Establish the protective conductor connections. • Reinstall the monitor housing. System with Polydoros LX chapter 3 System with Polydoros SX chapter 4 LITHOSTAR Multiline RXL2-120.812.01 Page 14 of 14 Siemens AG System Rev. 02 10.04 CS PS 24 Medical Solutions...
  • Page 23: General Information

    Water hoses 5 and 8 may only be shortened by max. 5 m. CAUTION Do not step on the hoses. Avoid small loops and kinks as this may damage them. Siemens AG RXL2-120.812.01 Page 1 of 20 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 24 Cable harness, green, from unit (K3, K4..) Cable harness, green, from unit (K8, K9..) 3rd monitor on monitor trolley (optional) Video cable 3rd monitor Mounting rail for cable harness Fig. 2 LITHOSTAR Multiline RXL2-120.812.01 Page 2 of 20 Siemens AG System Rev. 02 10.04...
  • Page 25: Connections/Cable Locations In The Generator Cabinet (Part A)

    - K30.L1, L2, L3 (is switched over the GS breaker with generator ON). - K30. N and K30. terminal pins ( /Fig. 3). • Strain-relieve the power harness (shielding under the clamp). Siemens AG RXL2-120.812.01 Page 3 of 20 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 26 • Plug in the control console harness on board D160.X9 as shown in Table 2 /Fig. 3). • Strain- relieve the harness on the side using cable ties. LITHOSTAR Multiline RXL2-120.812.01 Page 4 of 20 Siemens AG System Rev. 02 10.04...
  • Page 27 L2, N, PE 1 x 6 mm Protective conductor PE control console M16.PE Right cable harness Tab. 3 Siemens AG RXL2-120.812.01 Page 5 of 20 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 28: Connections Of The Options And Their Cable Locations In The A12

    Cable harness, green, from the unit (K3, K4..) Cable harness, green, from the unit (K8, K9..) 3rd monitor on the monitor trolley (option) Video cable 3rd monitor Rail for cable harness Fig. 4 LITHOSTAR Multiline RXL2-120.812.01 Page 6 of 20 Siemens AG System Rev. 02 10.04...
  • Page 29 ECG control Patient monitor "SYNC" A12/N11/D11.k14 Tab. 4 The monitor cable contains more cable than necessary for connecting the LITHOSTAR Multiline. Roll up the additional cables and place them in the control cabinet. Siemens AG RXL2-120.812.01 Page 7 of 20...
  • Page 30: Connections And Cable Locations In The A12 Electronics Cabinet

    Cable harness, green, from the unit (K3, K4..) Cable harness, green, from the unit (K8, K9..) 3rd monitor on the monitor trolley (option) Video cable 3rd monitor Mounting rail for cable harness Fig. 5 LITHOSTAR Multiline RXL2-120.812.01 Page 8 of 20 Siemens AG System Rev. 02 10.04...
  • Page 31 D31.X33 N11/D11.K6 brake control 9 pole connector k12 Zoom selection N11/D11.K12 9 pole connector k13 Respirator sensor D27.X1 N11/D11.K13 connection Tab. 6 Siemens AG RXL2-120.812.01 Page 9 of 20 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 32 • After connecting the MEMOSKOP cabling, reinstall the MEMOSKOP cover. The cable shielding must be under the corresponding clamp. LITHOSTAR Multiline RXL2-120.812.01 Page 10 of 20 Siemens AG System Rev.
  • Page 33: Connections/Cable Locations In The A13 Shock Wave Cabinet

    Make sure there are no kinks in the hoses and that they are secured. Connection point for blue cable har- Fig. 6 Siemens AG RXL2-120.812.01 Page 11 of 20 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 34 - Insert the connector of high voltage cable K26 on the bottom of the charger until it locks audibly into position. - The connection (jumper) between and 0V must be present. Fig. 7 LITHOSTAR Multiline RXL2-120.812.01 Page 12 of 20 Siemens AG System Rev. 02 10.04...
  • Page 35: Connections/Cable Locations In The Generator Cabinet (Part. B)

    Connect the rotating anode cable to the breaker of the anode starter ( /Fig. 8): On breaker, contact: K31/R2 K31/R4 K32/R2 Anode cable leads: I / 1 II / 2 Siemens AG RXL2-120.812.01 Page 13 of 20 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 36 (part no. 44 10 023 RV090 1 liter). • Insert the high voltage plug without silicone disk but with silicone gasket into the correct receptacle of H1 (Workstation 1). LITHOSTAR Multiline RXL2-120.812.01 Page 14 of 20 Siemens AG System Rev.
  • Page 37 Reinstall the guard with the symbols (1/Fig. 11). • Check the nuts on the protective conductor studs (8/Fig. 12) and tighten them, if necessary. Fig. 12 Siemens AG RXL2-120.812.01 Page 15 of 20 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 38: Connections/Harness Locations In The Generator Cabinet (Part C)

    Strain-relieve the power cable on the bottom plate of POLYDOROS LX. Do not allow this to connect to any existing shielding on the power cable. • Reinstall the cover over the knife breakers. LITHOSTAR Multiline RXL2-120.812.01 Page 16 of 20 Siemens AG System Rev.
  • Page 39 Remove the corresponding jumper and connect the function according to wiring diagram X2169-11. If necessary, pull the left part of the D160.X6 plug out from the side. Siemens AG RXL2-120.812.01 Page 17 of 20 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24...
  • Page 40 Plug the fiber optic cable into N11 on board D6 (according to color code). Secure the fiber optic cable with cable clamps to the right side of the cabinet. • Connect the corrugated hose to the Sonoline. LITHOSTAR Multiline RXL2-120.812.01 Page 18 of 20 Siemens AG System Rev.
  • Page 41 Clamp for power cable (A) Protective conductor Corrugated hose from SONOLINE Cable outlet to cabinets Clamp for corrugated hose Fig. 15 Siemens AG RXL2-120.812.01 Page 19 of 20 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 42: Fastening Of Plug, Sonoline

    Tighten the counternut (1/Fig. 17). CE approval is valid for the entire system only. If the ultrasound NOTE unit is removed, then this does not retain the required CE appro- val. LITHOSTAR Multiline RXL2-120.812.01 Page 20 of 20 Siemens AG System Rev.
  • Page 43: General Information

    Water hoses 5 and 8 may only be shortened by max. 5 m. CAUTION Do not step on the hoses. Avoid small loops and kinks as this may damage them. Siemens AG RXL2-120.812.01 Page 1 of 24 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 44: Connections And Cable Locations In The A12 Electronics Cabinet

    Cable harness, green, from unit (K3, K4..) Cable harness, green, from unit (K8, K9..) 3rd monitor on monitor trolley (optional) Video cable 3rd monitor Mounting rail for cable harness Fig. 2 LITHOSTAR Multiline RXL2-120.812.01 Page 2 of 24 Siemens AG System Rev. 02 10.04...
  • Page 45: Overview Of Cable Run In The Power Cabinet

    Overview of cable run in the power cabinet Route the cable in the power cabinet from the left or right only. Fig. 3 Siemens AG RXL2-120.812.01 Page 3 of 24 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 46: Connections/Harness Locations In The Generator Cabinet (Part A)

    This cable is located in the “System operating console-Electronics Cabinet” zipper hose Type of cable/ In Control Function in AC Generator connector Console 15 pole, Canon System ON/OFF Door D160.X9 Tab. 2 LITHOSTAR Multiline RXL2-120.812.01 Page 4 of 24 Siemens AG System Rev. 02 10.04 CS PS 24 Medical Solutions...
  • Page 47 L2, N, PE 1 x 6 mm Protective conductor PE operating M16.PE right cable harness console Tab. 3 Siemens AG RXL2-120.812.01 Page 5 of 24 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 48: Connections Of The Options And Their Cable Positions In The A12

    Cable harness, green, from the unit (K3, K4..) Cable harness, green, from the unit (K8, K9..) 3rd monitor on the monitor trolley (option) Video cable 3rd monitor Mounting rail for cable harness Fig. 4 LITHOSTAR Multiline RXL2-120.812.01 Page 6 of 24 Siemens AG System Rev. 02 10.04...
  • Page 49 ECG control Patient monitor "SYNC" A12/N11/D11.k14 Tab. 4 The monitor cable contains more cable than necessary for connecting the LITHOSTAR Multiline. Roll up the additional cables and place them in the control cabinet. Siemens AG RXL2-120.812.01 Page 7 of 24...
  • Page 50: Connections And Cable Locations In The A12 Electronics Cabinet And In The Control Console

    Cable harness, green, from the unit (K3, K4..) Cable harness, green, from the unit (K8, K9..) 3rd monitor on the monitor trolley (option) Video cable 3rd monitor Mounting rail for cable harness Fig. 5 LITHOSTAR Multiline RXL2-120.812.01 Page 8 of 24 Siemens AG System Rev. 02 10.04...
  • Page 51 D31.X33 N11/D11.K6 brake control 9 pole connector k12 Zoom selection N11/D11.K12 9 pole connector k13 Respirator sensor D27.X1 N11/D11.K13 connection Tab. 6 Siemens AG RXL2-120.812.01 Page 9 of 24 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 52 • After connecting the MEMOSKOP cabling, reinstall the MEMOSKOP cover panel. The cable shielding must be under the corresponding clamp. LITHOSTAR Multiline RXL2-120.812.01 Page 10 of 24 Siemens AG System Rev.
  • Page 53: Connections/Cable Locations In The A13 Shock Wave Cabinet

    Make sure there are no kinks in the hoses and that they are secured. Connection point for blue cable har- Fig. 6 Siemens AG RXL2-120.812.01 Page 11 of 24 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 54 - Insert the connector of high voltage cable K26 on the bottom of the charger until it locks audibly into position. - The jumper between and 0V must be present. Fig. 7 LITHOSTAR Multiline RXL2-120.812.01 Page 12 of 24 Siemens AG System Rev. 02 10.04...
  • Page 55: Overview Of Cable Run In The Power Cabinet

    Overview of cable run in the power cabinet Route the cable in the power cabinet from the left or right only. Fig. 8 Siemens AG RXL2-120.812.01 Page 13 of 24 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 56: Connections/Cable Locations In The Generator Cabinet

    Connect the rotating anode cable to the K3 breaker of the anode starter ( /Fig. 8): On breaker, contact: K31/R2 K31/R4 K32/R2 Anode cable leads: I / 1 II / 2 LITHOSTAR Multiline RXL2-120.812.01 Page 14 of 24 Siemens AG System Rev. 02 10.04 CS PS 24...
  • Page 57 Insert the high voltage plug without silicone disk but with silicone gasket into the correct receptacle of H1 (Workstation 1). • Slide the H1 high voltage transformer into the generator cabinet. Siemens AG RXL2-120.812.01 Page 15 of 24 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 58 (1/Fig. 10) of the mount. • Use cable ties to strain-relieve the cables (8/Fig. 13). • Carefully remove the plastic guard plate for board D220 with symbols (1/Fig. 12). LITHOSTAR Multiline RXL2-120.812.01 Page 16 of 24 Siemens AG System Rev. 02 10.04...
  • Page 59 Reinstall the guard with the symbols (1/Fig. 12). • Check the nuts on the protective conductor studs (7/Fig. 13) and tighten them, if neces- sary. Siemens AG RXL2-120.812.01 Page 17 of 24 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 60: Overview Of Cable Run In The Power Cabinet

    Connections with POLYDOROS SX 65 Overview of cable run in the power cabinet Route the cable in the power cabinet from the left or right only. T2 11 Fig. 14 LITHOSTAR Multiline RXL2-120.812.01 Page 18 of 24 Siemens AG System Rev. 02 10.04...
  • Page 61: Connections/Harness Locations In The Generator Cabinet (Part C)

    2 x 0.75 mm Radiation protection M16.D160.X61 Door contact 2 x 0.75 mm Radiation buzzer M16.D160.X61 X-ray display lamps Radiation display Tab. 10 option Siemens AG RXL2-120.812.01 Page 19 of 24 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 62: Monitoring Devices And Indicators For Radiation Protection

    Attach an indicator lamp in the vicinity of the tube assembly (24 V ~, max. 5 W) so that it is clearly visible from the control console. Connect the lamp 24 V ∼ and D160.X61.6 (0 V for AP1 to: D160.X61.5 LITHOSTAR Multiline RXL2-120.812.01 Page 20 of 24 Siemens AG System Rev. 02 10.04...
  • Page 63 RXL2-120.034...” Site Adjustments” in the section “Room light” as required. Connect contactor connection to: D160.X64.5 (24 V ~) and D160.X64.6 (0 V Siemens AG RXL2-120.812.01 Page 21 of 24 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 64 Move board D6 slightly away from N11 to facilitate this. • Plug the fiber optic cable into N11 on board D6 (according to color code). • Connect the corrugated hose to the Sonoline. LITHOSTAR Multiline RXL2-120.812.01 Page 22 of 24 Siemens AG System Rev.
  • Page 65 Clamp for power cable (A) Protective conductor Corrugated hose from SONOLINE Cable outlet to cabinets Clamp for corrugated hose Fig. 16 Siemens AG RXL2-120.812.01 Page 23 of 24 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 66: Fastening Of Plug, Sonoline

    Tighten the counternut (1/Fig. 17). CE approval is valid for the entire system only. If the ultrasound NOTE unit is removed, then this does not retain the required CE appro- val. LITHOSTAR Multiline RXL2-120.812.01 Page 24 of 24 Siemens AG System Rev.
  • Page 67: Attaching The Remaining Panels

    Install the X-ray tube housing and attach them together ( /Fig. 2). • Secure the EMC metal shielding with screws to the designated location. • Close all front walls of the cabinets. Siemens AG RXL2-120.812.01 Page 1 of 2 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 68: Adapting The Other Accessories

    Complete the installation protocol in register 3 of the log book. Adapting the Other Accessories • Perform a test installation of all accessories that have been included in the shipment in accordance with the Operating Instructions LITHOSTAR Multiline RXL2-120.812.01 Page 2 of 2 Siemens AG System Rev.
  • Page 69 6 - 1 Chap. 0 Cover, Contents, Revision newly generated. Chap. 4 - 24 Page new added. Chap. 3 - 20 Page new added. Siemens AG RXL2-120.812.01 Page 1 of 2 LITHOSTAR Multiline Medical Solutions Rev. 02 10.04 CS PS 24 System...
  • Page 70 6 - 2 Changes to previous version This page intentionally left blank. LITHOSTAR Multiline RXL2-120.812.01 Page 2 of 2 Siemens AG System Rev. 02 10.04 CS PS 24 Medical Solutions...

Table of Contents