Fluid Type

Reynolds Correction

Programming Site Data
1. The selections for fluid type vary depending on whether the
Tracking Window is enabled or disabled. Press [
select the desired fluid and press [ENTER] . Refer to Table 2-2
below for a list of available fluids.
Table 2-2: Fluid Types
Tracking Window = NO
WATER
OTHER
2. If you selected OTHER , enter the additional information required
by using the arrow keys. Press [
the desired location and press
decrease the number. Then press [ENTER] .
]
1. Using [
and [ ], select
Correction Factor or select
Correction Factor. Then press [ENTER] .
Note: usually, Reynolds Correction should be set to
2. Do one of the following:
If you selected OFF , enter the Calibration Factor and press
[ENTER] . Then, proceed to one of the following sections:
Clamp-on Transducers - proceed to Number of Traverses
and Transducer Spacing on the next page.
Wetted Transducers - The meter returns to the
Channel PROGRAM window. To complete initial setup of
the AT868, you must enter data in the GLOBL-SYSTM
submenu on page 2-12.
If you selected ACTIV , proceed to KV Input Selection on the next
page.
September 2004
]
Tracking Window = YES
W100 (Water, 0°-100°C)
W260 (Water, 0°-260°C)
Oil, Tracking
OTHER
]
and [ ] to move the cursor to
[ ] and [ ]
to increase or
to activate the Reynolds
Activ
to deactivate the Reynolds
Off
Activ
and [ ] to
.
2-9