Section 5: Operation
Figure 5.5: Stage 2: Repressurization
Figure 5.5: Stage 2: Repressurization
At completion of Stage 1, the left solenoid valve is de-energized. Air pressure on the outside of the right diaphragm increases as air flows through the tiny bleed hole
in the diaphragm. The air pressure on the outside of the diaphragm quickly equalizes with the internal air pressure of the dryer allowing the small spring on the outside
of the diaphragm to press the diaphragm against its seat, keeping air from exiting the silencer.
Note: Any air flowing through the dryer, passes through both towers.
Water
1.0 µ
Separator
Pre-Filter
IN
TIMING CHART:
SV 1
(Left Solenoid Control Valve)
SV 2
(Right Solenoid Control Valve)
DV 1
(Prefilter Drain Solenoid Valve)
Seconds: 0
22
Alternate Inlet
To Bottom Valve
Left
S.V.
120
170
Alternate Outlet
Right
S.V.
ON
OFF
ON
OFF
2 Seconds
ON
OFF
290
340
Heatless Desiccant Dryers |
0.01 µ
After Filter
OUT
LEGEND:
Wet
Purge
Dry
Instruction Manual