Electrical Installation - Beko Drypoint ACC 4 Instruction/Technical Manual

Table of Contents

Advertisement

Section 4: Electrical Installation

Electrical Installation

Connection
The dryer is designed to operate on either AC or DC supply
voltage.
Electrical wiring must comply with local regulations. Voltage
requirements must be confirmed to be within the specification
on the dryers rating plate.
Ensure only one power source is connected at any one time
and is connected to the correct socket as shown in figure 4.3
and 4.4.
The dryer controller is double insulated therefore no earth
is required on the power connector. External fuse to be
connected to plug.
The cable selection must suit local installation regulations and
be appropriate to power consumption as shown in the Power
Supply table.
How to wire a power connector
Figure 4.1 illustrates how to wire power connector. Please
refer to wiring diagram, figure 4.2, page 16, for further
information.
Heatless Desiccant Dryers |
Instruction Manual
Power Supply
Supply
12 VDC
24 VDC
100 VAC
115 VAC
230 VAC
240 VAC
Figure 4.1: Din connector
Amp
0.80
0.40
0.16
0.14
0.07
0.07
Gasket
Insert
Remove screw & pry
to remove insert
15