Huawei R100020G1 User Manual page 18

Charging module
Table of Contents

Advertisement

R100020G1 Charging Module
User Manual
Table 2-4 Nixie tube description
Display
Output voltage
Output current
Hardware address
Group number
Error code
Startup/Shutdown
Software version
Issue 05 (2021-11-16)
Description
● No decimal places. The precision is 1 V when the
● Parameters can be set using buttons only in the setting
● The last digit is a decimal with the precision of 0.1 A.
● Parameters can be set using buttons only in the setting
● Adr is displayed by default. Hold down the button to
● On the setting screen (blinking), flip the first digit to
● After the hardware address is modified, the group
● Parameters can be set using buttons and the settings
● GrP is displayed by default. Hold down the button to
● The group number is displayed in decimal format.
● Parameters can be set only under the company
● Parameters can be set using buttons and the settings
● The high-order character is displayed as E, and the
● Parameters cannot be set using buttons.
● on: startup; oFF: shutdown
● Parameters can be set using buttons only in the setting
● The value is displayed as digits.
● Parameters cannot be set using buttons.
Copyright © Huawei Digital Power Technologies Co., Ltd.
voltage ranges from 0 V to 999 V. There is no precision
requirement when the voltage is greater than 999 V.
The minimum displayed value is 000 V and the
maximum displayed value is 999 V.
mode but the settings are not saved upon power
failure.
The minimum displayed value is 00.0 A and the
maximum displayed value is 99.9 A.
mode but the settings are not saved upon power
failure.
enter the address display screen (static).
enter the CCC screen. The default hardware address
127 (decimal) can be restored.
number is restored to the default value.
are saved upon power failure.
enter the group number display screen (static).
protocol. Setting is not supported under third-party
protocol.
are saved upon power failure.
middle- and low-order characters are displayed as
digits.
mode but the settings are not saved upon power
failure.