4 SAFETY MONITORING FUNCTIONS
(b) When deceleration fails with SS1 enabled
Elapsed time from when the SS1 command is enabled is measured. If the motors fail to stop by the time the
SS1 deceleration monitoring time elapses, error H2280 occurs. The operation sequence is shown below:
Speed
速度
Safe stop speed
安全停止速度
Enabled
有効
SS1 command
SS1指令
Disabled
無効
Enabled
有効
SS1 monitoring
SS1監視
Disabled
無効
Enabled
有効
STO monitoring
STO監視
Disabled
無効
Enabled
SS1エラー
有効
SS1 error
Disabled
(H2280)
無効
(c) When the SS1 command is canceled with SS1 enabled before the STO monitoring state becomes
active
Once the SS1 command is enabled, the SS1 monitoring cannot be canceled until the STO monitoring state
becomes active (the deceleration and stop operation cannot be canceled). After the STO monitoring state
becomes active, the SS1 monitoring is canceled.
Speed command
速度指令
Safe stop speed
Enabled
有効
SS1 command
SS1指令
無効
Disabled
Enabled
有効
SS1 monitoring
SS1監視
Disabled
無効
Enabled
有効
STO monitoring
STO監視
Disabled
無効
Fig. 4-36: When the SS1 command is canceled with SS1 enabled before the STO monitoring state becomes
(d) When the origin has not been configured
When the origin has not been configured, inputting the SS1 command (emergency stop, error) activates the
STO monitoring state immediately.
4-46 Safety Monitoring Functions
Speed
速度
Command
指令
Deceleration delay
減速遅延時間
Fig. 4-35: When deceleration fails with SS1 enabled
Speed
速度
Command
指令
安全停止速度
SS1
STO
Feedback
フィードバック
SS1
STO
Feedback
フィードバック
Deceleration delay
減速遅延時間
active
Time
時間
Time
時間