User Setting Tool Operation Procedures - Sharp PN-L803C Service Manual

Touch display / touch pen
Hide thumbs Also See for PN-L803C:
Table of Contents

Advertisement

11. USER SETTING TOOL OPERATION PROCEDURES

This tool allows saving the setting contents of the machine into a PC.
If the user's request on the setting is known in advance, make the requested setting by using a machine of the same model in the sales
depot before installing the product in the user's site, and save the setting to a PC. After installation, transfer the setting in the PC to the
user's PC. (There are some setting contents which cannot be saved.)
<CAUTION>
- The saved user setting values can be used with the same model of the monitor.
- The operation of the monitor cannot be guaranteed when the saved user setting values are written to the different model of the monitor.
There are two kinds of the procedures to save or set the user setting values.
- Use the service tool
Refer to the "USER SETTING TOOL OPERATION PROCEDURE".
- Use the USB flash drive
Refer to the "SAVE OR RESTORE THE USER SETTING VALUES TO THE USB FALSH DRIVE".
11-1. OPERATING CONDITIONS OF THE USER
SETTING VALUE TOOL
The operating conditions of the Gamma setting read tool of the
information display are as follows.
- Windows 8/8.1
OS
- Windows Vista
(32bit/64bit)
- Windows 7
- RS-232C port which is recognized as COM
port (with communication speed: 9600,
Communication
19200, 38400bps)
port
- LAN(100 BASE-TX / 10BASE-TX)
When connected to the information display
with a LAN cable
Connect the monitor and the PC by the cross cable or the straight
cable through the hub. When the monitor and the PC is connected
directly by the cross cable, the settings for the monitor and the PC
needs to be done.
When the monitor is connected to the network, ask your system
administrator about how to set the PC for connecting the monitor.
(MEMO)
This tool cannot be operated correctly when the monitor is in the
power waiting state or the signal waiting state. In this case, send
the input signal to the monitor or set the power management to
OFF.
PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 18
11-2. BOOTING THE USER SETTING VALUE
TOOL
Press [User Setting value] button of the service tool launcher.
11-3. USER SETTING VALUE BACKUP
PROCEDURES
1 ) Press [Connection Setting] button to make connection setting.
2 ) Turn ON the information display.
3 ) Select the range of set values to be backed up.
All user setting values
All
User setting values related to pictures only
Picture Only
4 ) Press [Read] button.
5 ) The dialog for saving the file is displayed. The initial file name
is "XXprop_ [Model name]_[Serial number]
[Date(YYYYMMDD)]_[Data type].bak".
Check the file name and press [Save] button to save the user
setting values.
<CAUTION>
When you used the saved data for the restoration of the machine,
do not change the file name.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pn-80tc3Pn-zl03

Table of Contents