2
Procedure of Replacement/Cleaning > Fixing area > Replacing the Fixing Assembly > Replacement procedure
4) Remove the Fixing Upper Cover [1].
• 1 Screw [2]
• 2 Hooks [3]
[3]
2
Procedure of Replacement/Cleaning > Fixing area > Replacing the Fixing Assembly > Replacement procedure
[1]
1x
[2]
F-2-15
CAUTION:
Be sure to check that the 2 hooks [3] are hooked when installing the Fixing Upper Cover
[1].
[3]
[1]
If the 2 hooks [3] are not hooked, the Fixing Upper Cover [1] may hit the duct [5] when
storing the Fixing Feed Unit [4].
[5]
[1]
2-9
[3]
[3]
[3]
F-2-16
[4]
F-2-17
2-9