Address PST High Part
Address PST Low Part
Amount of Data
1070 072 196-101 (00.06) GB
General Information Regarding BUEP-E and BUEP19E
Parameter
Word
PW10
Address PST high part
Example
F0
H
ZS400
In this parameter, the block address of the module to which the PST com-
mand is referred, is specified.
Parameter
Word
PW11
Address PST low part
Example
46
H
70 bytes
In the low part of the PST address, the byte address (offset) of the used com-
mand is specified.
Parameter
Word
PW12
Amount of data (in data types) according to type of operand
Example
28
H
Amount = 40
In this parameter, it is specified how much data -- in relation to the operand
type -- has to be transferred.
If the operand type 'mask' is used, the amount of data must be set to 1. Then,
the double length (setting mask and resetting mask) of the type that is speci-
fied in the mask identifier (e.g. the word mask) is always transmitted in the
following order: low part, high part.
Example:
Parameter
Word
Byte
Word
Double word
Quad word
Byte mask
Word mask
Double word
mask
Quad word
mask
Contents
Contents
Contents
PW11
Number in Bytes
3
7
2
5
1
1
1
1
7- -7
3
14
8
40
2
4
8
16