7- -2
General Information Regarding BUEP-E and BUEP19E
7.1
Parameters BUEP-E / BUEP19E
The job parameters correspond to the parameters as they are defined for
BUEP19E. In addition to this structure, the internet address of the PST mod-
ule is entered in the PW14 and PW15 parameter.
Parameter
Word
PW1
PLC reaction
PW2
RSS number
PW3
PW4
Type of command: E/A
PW5
Command code: AST
PW6
PW7
PW8
PW9
PW10
PW11
PW12
Amount of data corresponds to type of operand
PW13
Process coordination point
PW14
PW15
PW16
Contents
High Byte
Job number
Type of operand: Byte/Word
Command attribute AST
Address AST high part (ZS block address)
Address AST low part
Command attribute PST
Address PST high part (ZS block address)
Address PST low part
Field coordination point
Internet address high part
Internet address low part
Reserved
1070 072 196-101 (00.06) GB
Low Byte
Error code
Channel number
Command code: PST