13. MODEL NAME SETTING PROCEDURES
13-1. OPERATING CONDITIONS OF THE MODEL
NAME SETTING TOOL
The operating conditions of the Gamma setting read tool of the
information display are as follows.
・Windows XP
・Windows Vista
・Windows 7
OS
An authorized copying and distribution
(32bit Only)
package of Microsoft Visual C++ 2005 or
later is required to be installed.
・ RS-232C port recognized as a COM port
Communication
(Which allows communication in 9600/
port
19200/ 38400bps.)
■When connected to the information display with an RS-232C
cable
The required RS-232C cable is as shown below. Connect the
PC's COM port and the RS-232C input terminal of the display
with the cable.
* The conversion cable for RS-232C connection is necessary.
Straight cable (D-SUB 9 pin female -
RS-232C cable
female)
RS-232 straight cable
(commercially available)
13-2. START-UP OF THE MODEL NAME SETTING
TOOL
Press [Model Name] button of the Service Tool Launcher.
PN-K321/K322B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 25
RS-232C input
terminal
PC
To COM port
13-3. MODEL NAME SETTING PROCEDURES
The procedures of setting model names with use of the Model
Name
Setting Tool are as follows.
1 ) Input the model name in the field of Write Data.
Normally, the model name has been already input at the time
of start-up. Therefore you don't need to change it.
2 ) Press [Connection Setting...] button to configure the
communication settings.
3 ) Press [Write] button.
4 ) Press [Read] button, and confirm that the model name is
displayed in the Read Data field.
13-4. MODEL NAME CHECK METHOD
Press [Display] button to indicate the display information by the
button on the side of the monitor , and check the model name.