Download Print this page

Sharp PN-K321 Service Manual page 55

Hide thumbs Also See for PN-K321:

Advertisement

: '13/Dec
11. SERIAL NUMBER WRITING PROCEDURES
11-1. OPERATING CONDITIONS OF THE SERIAL
NUMBER SETTING TOOL
The operating conditions of the Gamma setting read tool of the
information display are as follows.
・Windows XP
・Windows Vista
・Windows 7
OS
An authorized copying and distribution
(32bit Only)
package of Microsoft Visual C++ 2005 or
later is required to be installed.
・ RS-232C port recognized as a COM port
Communication
(Which allows communication in 9600/
port
19200/ 38400bps.)
■When connected to the information display with an RS-232C
cable
The required RS-232C cable is as shown below. Connect the
PC's COM port and the RS-232C input terminal of the display with
the cable.
* The conversion cable for RS-232C connection is necessary.
Straight cable (D-SUB 9 pin female -
RS-232C cable
female)
RS-232 straight cable
(commercially available)
11-2. START-UP OF THE SERIAL NUMBER
SETTING TOOL
Press [Serial Number] button of the Service Tool Launcher.
PN-K321/K322B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 23
RS-232C input
terminal
PC
To COM port
11-3. SERIAL NUMBER SETTING PROCEDURES
The procedures of setting serial numbers with use of the Serial
Number Setting Tool are as follows.
1 ) Press [Connection Setting...] button to configure the
communication settings.
2 ) Input the serial number you need to set in the field of Write
Data.
3 ) Press [Write] button.
4 ) Press [Read] button, and confirm that the set serial number is
displayed in the Read Data field.
11-4. SERIAL NUMBER CHECK METHOD
Display [INFORMATION] > [OTHERS] menu to indicate the
display information, and check the serial number by pressing the
button on the side of the monitor .

Advertisement

loading

This manual is also suitable for:

Pn-k321hPn-k322bPn-k322bh