NOTE: The configuration parameters for the Aux2 output is the same as shown below for Aux1.
Aux1 Config.
+ to view/change
Aux1 Function
Manual On/Off
for manual on/off, countdown
timer and timeclock functions
Aux1 Relay
Standard
for all functions except solar and
low speed of 2-speed filter pump and dimmer
Aux1 Interlock
Disabled
for all functions except
low speed of 2-speed filter pump
Aux1 Freeze
Enabled
WARNING: Do not use the Aqua Logic to control an automatic pool cover. Swim-
!
mers may become entrapped underneath the cover.
Super Chlorinate – if "Chlorinator" is enabled, this option allows the user to start a Super
Chlorinate cycle when the Lights button is pressed, rather than using the Settings Menu.
Note that only one button can me assigned to this function.
Lights Relay
This feature allows the user to select either "Standard" (default) or "Dimmer" type relay for
the Lights output. The optional AQL-DIM dimmer kit must be installed if "Dimmer" is
desired. When "Dimmer" is selected, and the Lights output is manually turned on, the "+"
and "-" buttons adjust the level from 20% to 100% (default). The level is saved for the next
time the lights are turned from off to on.
Lights Interlock
If enabled, this feature will override the function (Manual On/Off, Countdown Timer,
Timeclock) selected above and turn the lights relay off when: filter pump is off, first 3
minutes of filter pump operation (allows the pump to prime and get water flowing), when the
pool/spa suction return valves are in any position other than "pool only", or for the first 3
minutes after solar turns on (allows air in the solar panels to be purged). Interlock is not
available for solar, low speed filter pump, or dimmer.
Lights Freeze Protection
This function helps protect equipment that is wired to the lights relay against freeze damage.
If Freeze Protection is enabled and the AIR temperature sensor falls below the selected freeze
temperature threshold, the Aqua Logic will energize the lights relay. IMPORTANT: this only
enables operation of the lights relay during freeze--see the "Filter Pump Config." menu to
enable freeze protection for the main circulation system. Freeze Protection is not available
for low speed filter pump or dimmer.
+
Push to access Aux1 options
>
Move to previous/next configuration menu item
Rotates between
+
Solar, Low speed of a 2-speed pump
>
Move to next menu item
+
Toggle between Standard (default) and Dimmer
>
Move to next menu item or previous/next configuration menu
+
Toggle between Enabled and Disabled (default) Aux1 Interlock
>
Move to next menu item
+
Toggle between Enabled (default) and Disabled Aux1 Freeze
>
Move to previous/next configuration menu
Aux1 Function
Manual On/Off (default)—the aux relay will alternate between turning on and off when the
aux button is pressed. There is no automatic control logic.
Countdown Timer – the aux relay will turn on when the AUX button is pressed and then will
turn off automatically after a programmed time (see Timers Menu, Operation Manual). The
AUX button can also be used to turn the output off.
Timeclock – the aux relay will turn-on and turn-off at the times set for the aux1 timeclock in
the Timers Menu. The AUX button can also be used to turn the output on and off.
Manual On/Off
(default)
options, and Super Chlorinate
18