is selected, then the pool/spa suction and return valve actuators should be connected to the
Aqua Logic. Pressing the POOL/SPA button on the display/keypad will allow the homeowner
to alternate between pool and spa operation.
Spa CountDn
This menu will appear only if Pool/Spa Setup is set to "Pool and Spa". This setting is the
time, after you manually switch the Pool/Spa valves to "Spa Only", until the Aqua Logic
automatically returns the valves to their previous positions. It is programmed in increments
of 5 minutes, from "Manual On/Off" (0 minutes) to "21:00" (21 hours). The filter is forced on
during this time period.
Spa Spillover
When spa spillover is "Enabled" and "Pool and Spa", the homeowner will be able to rotate
through "Pool Only" (both suction and return valves switched to pool), "Spa Only" (both
suction and return valves switched to spa) and "Spillover" (suction valve switched to pool
and return valve switched to spa) by successive presses of the "Pool/Spa) button.
Filter Operation
If "Spa Spillover" is selected, the Aqua Logic will automatically switch the pool/spa suction
and return valves to "spillover" at the start of the programmed pool filtering time period or
when the super-chlorinate function is turned on. The valves will remain in this position for
the remainder of the super-chlorinate period. This option is usually preferable because both
the pool and spa water will be filtered and sanitized.
If "Pool Only" is selected, then the Aqua Logic will switch the pool/spa valves to the "pool
only" position at the start of the programmed pool filtering time period or when the super-
chlorinate function is turned on. This may be desirable on some systems with in-floor
cleaners because it allows the cleaner to operate all the time the pool is being filtered and/or
the super chlorinate is running.
V1=Aux1, V2=Aux2
This menu appears only if the Pool/Spa Setup is "Pool Only" or "Spa Only". When enabled,
Valve 1 (return) will follow the Aux1 output and Valve 2 (suction) will follow the Aux2 output.
When disabled (default), the return and suction pool/spa valves function normally.
Filter Pump Config.
+ to view/change
Filter Pump
1 Speed
Freeze Protect
Enabled
Freeze Temp
38ºF
Filter Pump
Select single speed or 2-speed pump. If a 2-speed pump is configured, one of the AUX
relays must also be configured to control the low speed motor winding on the pump. See
page 3 for specific information regarding the control logic for 2-speed pump operation.
Freeze Protection
Freeze protection is used to protect the pool and plumbed equipment against freeze damage.
If freeze protection is enabled and the AIR temperature sensor falls below the freeze threshold
(see below), the Aqua Logic will turn on the filter pump to circulate the water. If "Pool and
Spa" is selected in the Pool/Spa sub-menu, the valves will also alternate between the pool
and spa every 30 minutes and the filter pump will turn off while the valves are turning. The
chlorinator will not operate if freeze protection is the only reason the pump is running.
Freeze Protection Temperature
Select the temperature to be used for freeze protection. Temperature is adjustable from 33ºF
- 42ºF (1ºC - 6ºC). 38ºF (3ºC) is default. This threshold will be used for all outputs that have
freeze protection enabled.
+
Push to access pump options
>
Move to previous/next configuration menu
+
+
Toggle between 1-speed (default) and 2-speed options
>
>
Move to next menu item
+
Toggle between Enabled (default) and Disabled Freeze Protection
>
Move to next menu item or previous/next configuration menu
+
Adjust the desired freeze protection temperature (33ºF - 42ºF)
>
Move to previous/next configuration menu
15
Need help?
Do you have a question about the Goldline Controls Aqua Logic AQL-P-4 and is the answer not in the manual?