ABB MAG-X 3000 Series Instruction Manual page 7

Magnetic flowmeters
Hide thumbs Also See for MAG-X 3000 Series:
Table of Contents

Advertisement

INSTRUCTION MANUAL 10DX3111A&G Sizes 14 - 24 Inches
SPECIFIC
CAUTIONS
Never allow any support for the Magnetic Flowmeter to bear upon
the inner surface of the meter pipe section, as the liner may become
damaged. (pg. 2-2)
Do not use a DC ohmmeter for this measurement as polarization
effects will produce completely erroneous data. (pg. 4-3)
Some of the IC devices used in the signal converter are static
sensitive and may be damaged by improper handling. When adjust-
ing or servicing the signal converter, use of a grounded wrist strap
is recommended to prevent inadvertant damage to the integral solid
state circuitry. (pg. 6-1)
For TEFLON-lined meters, replacement of the electrodes must not
be attempted in the field. The meter must be returned to the factory
for electrode replacement. (pg. 6-7)
Exercise extreme care when withdrawing the electrode from its seat
so that little or no tension is exerted on the connecting electrode
wire. If this wire should break within the meter pipe, the meter is not
repairable. (pg. 6-7)
II

Advertisement

Table of Contents
loading

This manual is also suitable for:

10dx311110dx3111a10dx3111g