9.3

Commissioning of the Pump Drive (Motor Control)

9.4

Commissioning the Pump

9.4.1

General Notes about Commissioning the Pump

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
For details on the commissioning order, please refer to the respective docu‐
mentation of the drive controller or firmware description.
Please observe the general safety instructions on the protection against haz‐
ardous movements.
For commissioning the internal gear pump PGM, necessarily observe the
operating instruction of the hydraulic system.
Commissioning of the internal gear pump requires basic mechanical and hy‐
draulical knowledge.
The commissioning of the internal gear pump may only be done by skil‐
led personnel (refer to "Rexroth Sytronix, Safety Notes and Instructions
on Use, Motor-Pump Unit", MNR R911339831).
If the internal gear pump PGM has not been assembled correctly, persons
could be injured and the product or the system could be damaged when com‐
missioning the internal gear pump.
Ensure a correct assembly of the internal gear pump by qualified per‐
sonnel before you take the internal gear pump into operation.
NOTICE
When commissioning the product, provide for absolute cleanness.
Make sure that no contamination may penetrate when sealing the meas‐
uring connections.
NOTICE
When commissioning or re-commissioning a machine and/or system
make sure that the suction and pressure lines of the internal gear pump
are filled with hydraulic fluid and remain filled also during operation.
DOK-SYTROX-MPAS1******-IT01-EN-P
Rexroth Sytronix SvP 70xx Motor-Pump Unit MPAS1
Contaminated hydraulic fluid could result in
wear and tear and malfunctions. In particular‐
ly foreign bodies like e.g. welding beats and
metal cuttings in the suction line may damage
the internal gear pump.
When commissioning the internal gear pump
with or without hydraulic fluid, the internal
gear pump is damaged or even damaged im‐