Product Storage; Storage Times - Bosch Rexroth Sytronix SvP 70 Series Operating Instruction

Motor-pump unit
Hide thumbs Also See for Rexroth Sytronix SvP 70 Series:
Table of Contents

Advertisement

DOK-SYTROX-MPAS1******-IT01-EN-P
Rexroth Sytronix SvP 70xx Motor-Pump Unit MPAS1
6.5

Product Storage

6.6

Storage Times

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Store the products in their original package at a dry, dust free, vibration free
and light protected place without direct solar radiation. Please observe
classes 1K2, 1B1, 1C1,1S1,1M2 specified for storage acc. to DIN EN
60721-3-2.
Please observe the following classification limitations:
Storage temperature -20 ... +60 ℃
Relative air humidity 5 ... 95 %
Absolute air humidity 1 ... 29 g/m³
No condensation
No ice formation/freezing
No occurrence of salt mist
NOTICE
Protect the products from dampness and corrosion.
Store them only in rainproof and dry rooms.
Before storage, discharge the liquid coolant from liquid-cooled
motors to avoid frost damage.
Additional measures must be taken on commissioning to preserve proper
functioning – irrespective of the storage time which may be longer than the
warranty period of our products. However, this does not involve any
additional warranty claims.
Motors
Bearing time / months
Measures for commissioning
> 1
> 12
> 60
Control all parts to be free of damage.
Check all electrical contacts to be free from corrosion.
Let the motor run in without load for one hour at 800 ... 1,000
Upm. In the case of a mounted pump, ensure that the pump does
not run dry.
Measure the insulation resistance. Dry the winding at a value of <
1kOhm per volt rated voltage.
Exchange bearings.
Exchange encoders.
Tab. 6-5:
Measures before commissioning motors that have been stored over a
prolonged period of time
Bosch Rexroth AG
Transport and Storage
Damage due to moisture and humidity!
37/83