Connection

8.1

Motor-Pump Unit Hydraulically Connected

8.2

Ready-made Connection Cables for MPAS1

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Remove the flange covers on suction and pressure connection.
Immediately wipe away outgoing hydraulic fluid.
Check the line for cleanliness.
Ensure that the line connection contains the specified sealings.
Lock O-rings with assembly grease against slipping , if necessary.
Now, hydraulically connect the pump according to the specifications of
the machine manufacturers.
For further information refer to mounting instruction: Rexroth Sytronix Motor-
Pump Unit MPAS1 PGM4 - MSK101 - Air Cooling
Material number: R911342449
W0054
HCS02.1E
W0070
W0070
HCS03.1E
W0100
W0150
W0036
W0054
HMS01.1N
W0070
W0110
W0150
Tab. 8-1:
Ready-made Connection Cables
Encoder Cables
The encoder cable used is RKG0047.
The order designation of ready-made cables consist of cable
number and length (e.g. RKL0047/010.0 for a cable length of 10.0
m).
Bosch Rexroth AG
MPAS1-PGM4NE-___NNNN-V__-
110CBHA
110DBHA
110EBHA
RKL0067
RKL0067
RKL0069
RKL0067
RKL0069
RKL0071
RKL0070
RKL0072
RKL0072
RKL0075
RKL0067
RKL0069
RKL0069
RKL0071
RKL0070
RKL0072
RKL0072
45/83