Fujitsu Scan Partner 300C Instruction Manual page 49

Table of Contents

Advertisement

7
Byte 0
1
Logical unit number
2
3
4
5
(a) EVPD (enable vital product data): Byte 1
This scanner does not support EVPD. If this bit is set to 1, the scanner returns the following error:
• Status key: B'OOOO1 '(CHECK CONDITION)
• Sense key: X'5'(ILLEGAL REQUEST)
(b) Page code: Byte 2
This scanner does not support page code. If this bit is set to 1, the scanner returns the following error:
• Status key: B'00001'(CHECK CONDITION)
• Sense key: x'5'(ILLEGAL REQUEST)
(C)Allocation length: Byte 4
This field specifies the storage area in bytes that the initiator allocates for inquiry data. If a 0 is set here,
inquiry data is not transferred, but this
phase when it has transferred either the bytes of inquiry data specified in this field or all of effective inquiry
data.
4
6
5
Operation code X'12'
Page Code
(Reserved)
Allocation length
Control byte
is
not regarded as an error. The target terminates the DATA IN
4-23
3
2
1
(Reserved)
0
EVPD

Advertisement

Table of Contents
loading

Table of Contents