Aisg/Ook Overcurrent Alarm Handling - Huawei APAA00001 User Manual

Portable aisg adapter
Table of Contents

Advertisement

APAA00001
User Manual
Table 4-1 Hardware fault alarm
Symptom
This alarm is reported
when the flash memory or
2
I
C bus inside the PAA is
faulty. In this situation, the
alarm indicator is steady
on. This alarm can be
queried using the PAA app.
Handling Method
Restart the PAA.
----End

4.2.2 AISG/OOK Overcurrent Alarm Handling

Background
If the ALD connected to the AISG or OOK port on the PAA has overly strong current or is
short-circuited, the PAA forcibly shuts down the external power supply and an AISG/OOK
overcurrent alarm is reported.
Table 4-2 describes the AISG/OOK overcurrent alarm.
Draft A (2015-06-12)
If the PAA communicates properly with the smartphone and the alarm is cleared after the
restart, no further actions are required.
If the alarm persists, the PAA has been damaged. In this case, replace the PAA with a
new one or contact Huawei technical support.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Impact on the
Severity
System
The data storage
Major
or read functions,
such as battery
status query and
board
temperature
query, may be
faulty.
4 System Maintenance
Cause
The read/write
function of the flash
memory is faulty.
The flash memory
fails.
2
The I
C bus is faulty.
2
The I
C bus fails.