SYDFED-2X, SYDFED-3X, SYHDFED-1X | Troubleshooting
Bosch Rexroth AG, Edition 11.2021, RE 30017-B
Fig. 35: Error/diagnostic memory

15.2.1 Error diagnosis

At pin 3 of the central connector the signal "drive ready" can be output. For this,
the factory assignment of the digital output to parameter P-0-0115, bit 1, must be
activated. This signal can be used to find out whether the control is active and that
no error message is present. Should an error message occur during operation or
the controller enable be withdrawn, this bit is set to 0.
Here, the following is valid:
Table 27: Messages
Meaning of the message
Electronics OK
Error message present or no controller
enable set
Output signal at pin 3
24 V
0 V