Bosch LTC 8900 Series Installation Manual
Hide thumbs Also See for LTC 8900 Series:
Table of Contents

Advertisement

LTC 8900 Series
en
Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch LTC 8900 Series

  • Page 1 LTC 8900 Series Installation Manual...
  • Page 3: Table Of Contents

    LTC 8900 Series Table of Contents | en Table of contents Safety Safety precautions Important safety instructions Important notices FCC & ICES compliance UL certification Bosch notices Unpacking Parts List Introduction Description Features System Components LTC 8904 Series CPU Bay...
  • Page 4 | Table of Contents LTC 8900 Series 5.12.2 Second Level LTC 8903 Series Terminations 5.12.3 LTC 8902 Series Terminators 5.13 System Data Connections 5.13.1 LTC 8904 Series CPU Data Connections 5.13.2 LTC 8902 Series and LTC 8903 Series Data Connections 5.13.3...
  • Page 5 LTC 8900 Series Table of Contents | en 6.17 LTC 8901 Series CPU Selection Switch Camera Phasing and Accessory Installation Camera Phasing Information External Sync Information System Keyboard Installation Signal Distribution Unit Hookup Alarm Interface Unit Hookup External Computer Interface Connections...
  • Page 6: Safety

    | Safety LTC 8900 Series Safety Sicherheitshinweise Safety Precautions VORSICHT: UM EINEN ELEKTRISCHEN SCHLAG ZU C A U T IO N : T O R E D U C E T H E R IS K O F VERMEIDEN, IST DIE ABDECKUNG (ODER RÜCKSEITE) E L E C T R IC S H O C K , D O N O T R E M O V E C O V E R NICHT ZU ENTFERNEN.
  • Page 7: Safety Precautions

    LTC 8900 Series Safety | en Veiligheidsmaatregelen Medidas de Segurança VOORZICHTIG: OPEN DE BEHUIZING OF DE CUIDADO: PARA REDUZIR O RISCO DE CHOQUE ACHTERKANT VAN HET APPARAAT NIET. ZO VERMINDERT ELÉCTRICO, NÃO RETIRE A TAMPA (OU A PARTE U HET RISICO OP ELEKTRISCHE SCHOKKEN. IN HET POSTERIOR).
  • Page 8: Important Safety Instructions

    | Safety LTC 8900 Series Warning! Medium risk: Indicates a potentially hazardous situation. If not avoided, this could result in minor or moderate bodily injury. Caution! Low risk: Indicates a potentially hazardous situation. If not avoided, this could result in property damage or risk of damage to the unit.
  • Page 9 LTC 8900 Series Safety | en Overloading - Do not overload outlets and extension cords. This can cause fire or electrical shock. Power supply cord and plug protection - Protect the power supply cord and plug from foot traffic, being pinched by items placed upon or against them at electrical outlets, and its exit from the unit.
  • Page 10: Important Notices

    17. Attachments, changes or modifications - Only use attachments/accessories specified by the manufacturer. Any change or modification of the equipment, not expressly approved by Bosch, could void the warranty or, in the case of an authorization agreement, authority to operate the equipment.
  • Page 11 LTC 8900 Series Safety | en – Connect outdoor equipment to the unit's inputs only after this unit has had its grounding plug connected to a grounded outlet or its ground terminal is properly connected to a ground source. –...
  • Page 12 Connecting System ground to Safety ground may result in ground loops that can disrupt the CCTV system. Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
  • Page 13: Fcc & Ices Compliance

    LTC 8900 Series Safety | en FCC & ICES compliance FCC & ICES Information (U.S.A. and Canadian Models Only) This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: – this device may not cause harmful interference, and –...
  • Page 14: Ul Certification

    Bosch notices Video loss Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
  • Page 15: Unpacking

    Verify that all the parts listed in the Parts List below are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. The original packing carton is the safest container in which to transport the unit and must be used if returning the unit for service.
  • Page 16: Introduction

    LTC 8900 Series Introduction This manual covers the installation of the Allegiant® LTC 8900 Series systems. Information on system operation and information on the PC software package (if applicable) are covered in their own respective manuals. Keep these and other manuals which are supplied along with the various accessory devices available for reference during system installation and configuration.
  • Page 17: System Components

    LTC 8900 Series System Components | en System Components LTC 8904 Series CPU Bay This unit provides central control for the entire system. It contains all the system's configuration information such as camera tables, alarm tables, sequences, etc. It is also the connection interface to the various external Allegiant Series accessory products such as keyboards, alarm interfaces, signal distribution units, etc.
  • Page 18: Ltc 8934/00 Video Output Modules

    | System Components LTC 8900 Series first input bay configuration are looped using video ribbon cables to the next group of input bays. This sequence continues for each LTC 8902 Series Output Bay in the system.Each LTC 8903 Series Input Bay includes one Data Receiver module (LTC 8918) and a power supply (LTC 8805).
  • Page 19: Ltc 8946/93 Lan Switches

    LTC 8900 Series System Components | en LTC 8946/93 LAN Switches The LTC 8946/93 is a 10/100Base-T Ethernet LAN switch that provides a communication link between the LTC 8904 Series main CPU bay and up to 11 of the system’s LTC 8902 Series and LTC 8903 Series matrix bays.
  • Page 20: Hardware Installation Procedure For Standard Systems Utilizing Ltc 8904 Series Cpu

    | Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series LTC 8900 Series Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU General Installation Considerations (Refer to Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 Series CPU, page 31, for Installation Procedure for redundant system configurations using LTC 8901 Series CPU.)
  • Page 21: Ltc 8904 Series Cpu Bay Installation

    Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU | LTC 8900 Series LTC 8946 LAN Switch LTC 8904 CPU Bay LTC 8902 LTC 8902 Monitor Bay Monitor Bay LTC 8903 LTC 8903 Camera Bay Camera Bay LTC 8903...
  • Page 22: Lan Switch Installation

    | Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series LTC 8900 Series LAN Switch Installation The LTC 8946/93 is a standard 10/100 Base-T network switch. Disregard the original manufacturers instructions supplied with the LAN switch(es). To use the switch(es) in the LTC 8900 system, follow the directions supplied in this manual ONLY.
  • Page 23: Module Insertion

    Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU | LTC 8900 Series Module Insertion A special tool is supplied with the system components, for insertion of the Data Receiver, Video Input Module, and Video Output Module boards into LTC 8902 and LTC 8903 Series equipment bays.
  • Page 24: Ltc 8918/01 Data Receiver Modules

    | Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series LTC 8900 Series Verify that switches located on dipswitch S1 and S3 are all OFF.On dipswitch S2 of the LTC 8916/01, verify that switches 1 to 4 are OFF. Switch 8 should be in the ON position. Switches...
  • Page 25: Ltc 8934/00 Video Output Modules

    Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU | LTC 8900 Series Camera Number Range 2817 to 3072 3073 to 3328 3329 to 3584 3585 to 3840 3841 to 4096 Table 5.2: LTC 8918/01 Data Receiver Module (used in LTC 8903 Series bays) S2 positions 1 through 4 LTC 8903 Series Camera bays will always be providing video signals (either directly, or via asecond LTC 8903 Series bay) to a specific LTC 8902 Series Monitor bay.
  • Page 26: Ltc 8921/00 Video Input Modules

    | Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series LTC 8900 Series Figure 5.6: Typical Video Output Module Insertion The LTC 8934/00 Video Output Modules contain five (5) 8-position dip switches. DIP switch S1001 is reserved and all switches should be left in the ON position.
  • Page 27: System Video Connections

    Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU | LTC 8900 Series All LTC 8921/00 Video Input Modules are identical and can be swapped anywhere within the bay without making any changes to the module except to maintain proper termination settings.
  • Page 28: Multiple Monitor Bay Consideration

    | Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series LTC 8900 Series The LTC 8903 Series bay s VIDEO OUT connectors are labeled A through D, and the Monitor Bay VIDEO BUS connectors are labeled CAMERA BAY OUTPUT A through CAMERA BAY OUTPUT D.
  • Page 29: Second Level Ltc 8903 Series Terminations

    Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU | LTC 8900 Series Each LTC 8921/00 VIM card provides outputs for 32 monitors. The LTC 8903 Series bay provides 64 outputs, two LTC 8921/00 VIM cards for each 32 inputs (when more than 32 monitors are being served by the LTC 8903 Series bay).
  • Page 30: Multiple Ltc 8946/93 Lan Switch Connections

    | Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series LTC 8900 Series The number of available LAN ports can be increased by cascading multiple LTC 8946/93 LAN switches. Each LTC 8946/93 provides 10 additional ports. Additional ports are only required in large systems with more than a combined total of 11 LTC 8902 Series and LTC 8903 Series bays.
  • Page 31: Hardware Installation Procedure For Redundant System Configuration Utilizing Ltc

    Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 LTC 8900 Series Series CPU | en Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 Series CPU Refer to for Installation Procedure for standard system configuration using LTC 8904 Series CPU.
  • Page 32: Ltc 8901 Series Cpu Design Features

    | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC LTC 8900 Series 8901 Series CPU Primary LTC 8910 Primary Controller Power Supply Primary CPU Primary LAN Keyboards 1-8 Alarm LTC 8917 Biphase Relay Board Console Comm 3 Mains...
  • Page 33: Ltc 8901 Series Cpu Design Features

    Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 LTC 8900 Series Series CPU | en LTC 8943/95 LTC 8901 CPU bay System Controller PC Default Settings: User: Administr ator Comm 3 Password: Bosch Secondary Comm 4 LAN Data Line...
  • Page 34: Video Bay Redundancy Considerations

    | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC LTC 8900 Series 8901 Series CPU With this in place, data coming from the in-use CPU will go to all other ports on both switches. This allows the video bays to be connected to any port on either switch (except port 1 or 2, which is reserved for the System Controller PC).
  • Page 35: General Installation Considerations

    Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 LTC 8900 Series Series CPU | en Cameras 1-256 LTC 8903 Camera Bay LTC 8902 Monitor Bay Logical Monitor Numbers 1-64 Monitors 1-64 Figure 6.3: Non Fault-tolerant 256 Camera x 64 Monitor System 6.1.6...
  • Page 36 | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC LTC 8900 Series 8901 Series CPU Cameras 1-256 LTC 8903 Camera Bay LTC 8903 Camera Bay LTC 8902 Monitor Bay LTC 8902 Monitor Bay Monitor Outputs 1-32 Monitor Outputs 65-96...
  • Page 37: Main Cpu Bay Installation

    72-in. EIA mounting racks Main CPU Bay Installation The LTC 8900 Series Main CPU Bay is supplied fully assembled and requires no user adjustments. Install CPU bay into the mounting rack. Note, rack-mounting screws and associated hardware are NOT included.
  • Page 38: Lan Switch Installation

    | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC LTC 8900 Series 8901 Series CPU P rim a ry B a ck-U p A L L E G IA N T M a trix C P U BOSCH...
  • Page 39: Pc Monitor Installation

    1GB. No anti-virus software is provided. If this PC will be connected to a network or the internet, Bosch strongly recommends that a user-supplied anti-virus software package is installed to provide protection. In the inadvertent chance that a catastrophic problem or other unforeseen act corrupts the operating system files, a “Recovery DVD”...
  • Page 40: Module Insertion

    | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC LTC 8900 Series 8901 Series CPU Install the power supply in the far right position of the bay, ensuring proper alignment and seating of the supply into the rear mating connector. Verify that the power supply ON/OFF switch is in the OFF position.
  • Page 41: Data Receiver Modules

    Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 LTC 8900 Series Series CPU | en IN S R -T O L Figure 6.8: Example of Insertion Tool Use Data Receiver Modules LTC 8902 Series Video Output bays are supplied with LTC 8916/01 Data Receiver modules.
  • Page 42: Ltc 8918/01 Data Receiver Modules

    | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC LTC 8900 Series 8901 Series CPU Monitor Range 257 to 320 321 to 384 385 to 448 449 to 512 Table 6.1: LTC 8916/01 Data Receiver Module Switch Positions (used in LTC 8902 Service Bays)
  • Page 43: Ltc 8934/00 Video Output Modules

    Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 LTC 8900 Series Series CPU | en Camera Number Range 3585 to 3840 3841 to 4096 Table 6.2: LTC 8918/01 Data Receiver Module (used in LTC 8903 Series bays) S2 positions 1 through 4 LTC 8903 Series Camera bays always provide video signals (either directly, or via a second LTC 8903 Series bay) to a specific LTC 8902 Series Monitor bay.
  • Page 44: Ltc 8921/00 Video Input Modules

    | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC LTC 8900 Series 8901 Series CPU Figure 6.10: Typical Video Output Module Insertion The LTC 8934/00 Video Output Modules contain five (5) 8-position dip switches. DIP switch S1001 is reserved and all switches should be left in the ON position.
  • Page 45: System Video Connections

    Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 LTC 8900 Series Series CPU | en All LTC 8921/00 Video Input Modules are identical and can be swapped anywhere within the bay without making any changes to the module, except to maintain proper termination settings.
  • Page 46: Multiple Monitor Bay Considerations

    | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC LTC 8900 Series 8901 Series CPU The LTC 8903 Series bay s VIDEO OUT connectors are labeled A through D, and the Monitor Bay VIDEO BUS connectors are labeled CAMERA BAY OUTPUT A through CAMERA BAY OUTPUT D.
  • Page 47: Second Level 8903 Series Terminations

    Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 LTC 8900 Series Series CPU | en LTC 8903 Series bay provides 64 outputs, two LTC 8921/00 VIM cards are required for each 32 inputs (when more than 32 monitors are being served by the LTC 8903 Series bay). In this case, inputs are shared by adjacent cards.
  • Page 48: Ltc 8902 Series And Ltc 8903 Series Data Connections

    | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC LTC 8900 Series 8901 Series CPU Note that the LTC 8943/95 System Controller PC is supplied with a third LAN port. This port is available for connecting the PC to the user s Ethernet network. Only those with advanced knowledge of Windows and network installations should attempt to use this interface.
  • Page 49 Once the Begin login box appears, press Ctrl + Alt + Del as indicated. When the login Information box appears, login as Administrator using the Password Bosch (only first letter is capitalized). Bosch Security Systems, Inc. Installation Manual...
  • Page 50: Ltc 8901 Series Cpu Relay Outputs And Buzzers

    | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC LTC 8900 Series 8901 Series CPU After the PC enters the Windows desktop screen, the Allegiant server program should start automatically. If the automatic feature has been disabled, find and double-click the Allegiant icon to open the Allegiant Server program.
  • Page 51: Ltc 8901 Series Cpu Selection Switch

    Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 LTC 8900 Series Series CPU | en Connector Functions Description Positions 7 & 8 Relay - Backup CPU Fault Normal open, closes when Backup CPU failure is detected 9 & 10...
  • Page 52: Camera Phasing And Accessory Installation

    Connect a maximum of 8 system keyboards to any of the 8 keyboard ports (modular phone type jacks) on the rear of the LTC 8900 Series CPU bay. Each keyboard is supplied with a 3 m (10 ft) cable for local hookups. The LTC 8900 Series CPU bay can provide power to keyboards up to 30 m (100 ft) away using the optional LTC 8558/00 hookup cable.
  • Page 53: Signal Distribution Unit Hookup

    Camera Phasing and Accessory Installation | en Signal Distribution Unit Hookup The LTC 8900 Series CPU bay provides a single Biphase control code output which can be connected to a LTC 8568 or LTC 8768 Signal Distribution unit. The Signal Distribution units...
  • Page 54 Cable pinout information can be found at the end of this manual. Attach the 9-pin male connector side of the cable to the LTC 8900 Series CPU bay connector labeled CONSOLE.
  • Page 55: Satellite System Configuration Installations

    LTC 8900 Series Satellite System Configuration Installations | en Satellite System Configuration Installations A satellite system configuration is usually used for a medium to large distributed system, or to obtain extremely large matrix sizes configured more conventionally. Typically, a single Main control site can be used to view/control cameras located both locally and at various remote satellite sites.
  • Page 56: Allegiant Satellite System Configuration Installations

    | Satellite System Configuration Installations LTC 8900 Series Allegiant Satellite System Configuration Installations Any Allegiant Series switcher model (LTC 8300, LTC 8500, LTC 8600, LTC 8800, or LTC 8900) can be used as a main site or a satellite site unit. All products are standard models, and the...
  • Page 57 LTC 8900 Series Satellite System Configuration Installations | en An Allegiant Biphase control data line from the code distribution unit at the Main site must be provided to each satellite site. This data line carries all pan/tilt/zoom control commands, in addition to the switching commands generated by the Main site switcher.
  • Page 58 | Satellite System Configuration Installations LTC 8900 Series Model No. Maximum Number of System Cameras LTC 8900 Series 6144 1. Camera inputs at all sites, plus trunk lines. The Main site system must be programmed via the Master Control Software LTC 8059/00 or the LTC 8850/00 GUI to identify camera trunk line inputs as well as remote satellite cameras.
  • Page 59 LTC 8900 Series Satellite System Configuration Installations | en Figure 8.3: Conceptual Diagram of an Allegiant Satellite Switching System Bosch Security Systems, Inc. Installation Manual 2015.01 | 10.6 |...
  • Page 60 | Satellite System Configuration Installations LTC 8900 Series Figure 8.4: Conceptual Diagram of a Dual Master Allegiant Satellite System 2015.01 | 10.6 | Installation Manual Bosch Security Systems, Inc.
  • Page 61 LTC 8900 Series Satellite System Configuration Installations | en Typical Allegiant ‘Primary’ Master Site 1 Typical System Monitors (Video from all sites) Typical PTZ Camera Video Allegiant BOSCH BOSCH ALLEGIANT Video Matrix Typical Biphase Biphase Data lines to all local...
  • Page 62: Satellite Site "Trunk Line" Monitor Outputs

    | Satellite System Configuration Installations LTC 8900 Series Satellite Site “Trunk Line” Monitor Outputs At each of the remote satellite sites, a desired number of monitor outputs from the switcher must be assigned as trunk lines. The number of trunk lines can range from 1 to the maximum number of monitor outputs provided by the switcher.
  • Page 63: Main Site Programming Requirements

    (33+ on LTC 8300 Series, 65+ on LTC 8500, 129+ on LTC 8600, 257+ on LTC 8800 Series, 4097+ on LTC 8900 Series). Enter the desired camera number, (the satellite bay that it is actually connected to), and select if either a local title will be used, or if the remotely generated title will be used.
  • Page 64 | Satellite System Configuration Installations LTC 8900 Series camera number lines in the table may be reserved at this time for future expansion. If a local title is specified, the camera’s title can also be entered at this time. Designate any local camera numbers appropriately, and enter their corresponding titles.
  • Page 65: Special Programming For "Cascaded" Satellite System Configurations

    LTC 8900 Series Satellite System Configuration Installations | en Figure 8.8: Main Site Sample Program Showing Monitor Start-Up Camera Numbers Special Programming for “Cascaded” Satellite System Configurations In a 3-tier cascaded satellite system, it is highly recommended for the system design to have more trunks lines between the intermediate master/satellite system and the 3rd level satellite system than there are between the top level master system and the intermediate system.
  • Page 66: Alarm Inputs In Satellite Systems

    | Satellite System Configuration Installations LTC 8900 Series In default cascaded satellite system configurations, satellite switching commands are not associated with a user priority level. When a switching command sent from a master site is received by a satellite, the switch selection can immediately be overridden by operators at the satellite location who have any priority level.
  • Page 67 LTC 8900 Series Satellite System Configuration Installations | en Keyboard Primary Controller Relay Out COM1 Console Alarm Primary Back Up Back Up Controller Biphase COM2 Switch Control Figure 8.10: Rear Panel View of LTC 8901 Series CPU Bay Figure 8.11: Ribbon Connector Key Polarity Diagram for Matrix Bays Bosch Security Systems, Inc.
  • Page 68 | Satellite System Configuration Installations LTC 8900 Series Figure 8.12: Graphical Summary of Data Receiver DIP Switch Settings for Systems Up to 2048 Cameras by 512 Monitors 2015.01 | 10.6 | Installation Manual Bosch Security Systems, Inc.
  • Page 69 LTC 8900 Series Satellite System Configuration Installations | en Figure 8.13: Rear Panel View of LTC 8902 Series and LTC 8903 Series Video Matrix Bays Bosch Security Systems, Inc. Installation Manual 2015.01 | 10.6 |...
  • Page 70 | Satellite System Configuration Installations LTC 8900 Series F01U289924 Figure 8.14: Cable and Accessory Diagrams 2015.01 | 10.6 | Installation Manual Bosch Security Systems, Inc.
  • Page 71 LTC 8900 Series Satellite System Configuration Installations | en BackUp LAN Comm Port 3 Comm Port 4 Comm Port 2 Mouse Port (Connect (To Primary (To BackUp 4x USB (Spare) (USB) to BackUp IP Controller of CPU) Controller of CPU)
  • Page 72 | Satellite System Configuration Installations LTC 8900 Series Up to 256 System Cameras can be Connected using 8 LTC 8808 Panels (Continue LTC 8808 Sequence as Necessary) Additional LTC 8808 Video Interconnect Panels for Additional System Cameras Camera 9...
  • Page 73 LTC 8900 Series Satellite System Configuration Installations | en Typical Connections for up to 64 System Monitors LTC 8808 Video LTC 8808 Video Interconnect Panel Interconnect Panel Lower Upper Lower Upper LTC 8809 LTC 8809 LTC 8809 LTC 8809 Ribbon Cable...
  • Page 74 | Satellite System Configuration Installations LTC 8900 Series LTC 8904 CPU Bay LAN Data from the CPU to Any Available Port P r o C u r v e 2 5 T 2 6 T S w i t c h...
  • Page 75 LTC 8900 Series Satellite System Configuration Installations | en LTC 8901 CPU Bay LTC 8943/95 System Controller PC Comm 3 Secondary Comm 4 LAN Data Line Digital I/O Board Primary LAN LAN 1 Data Line to Port 1 LTC 8944/93 LAN Switch...
  • Page 76 | Satellite System Configuration Installations LTC 8900 Series LTC 8901 CPU Bay LTC 8943/95 System Controller PC Comm 3 Secondary LAN Data Line Comm 4 Digital I/O Board Primary LAN LAN 1 Data Line to Port 1 LTC 8944/93 LAN Switch...
  • Page 77 LTC 8900 Series Satellite System Configuration Installations | en To M o n i to rs v i a LTC 8 8 0 8 V i de o I n te rc o n n e c t Pa n e l s LTC 8 9 0 2 M o n i to r "D "...
  • Page 78 | Satellite System Configuration Installations LTC 8900 Series User-supplied PC Running Master Control Software LTC 8904 Main CPU Bay or Optional GUI Software Up To 256 Cameras LTC 8905 LTC 8910 Power CPU Module Supply Multiple Data Cables LAN Data Lines...
  • Page 79 LTC 8900 Series Satellite System Configuration Installations | en LTC 8943 PC Running LTC 8901 Main CPU Bay Configuration Up To 256 Software LTC 8905 LTC 8905 Cameras Main Backup LTC 8910 Main LTC 8910 Backup Power Power CPU Module...
  • Page 80 | Satellite System Configuration Installations LTC 8900 Series LTC 8943 PC Running Configuration Additional Software Cameras LTC 8905 LTC 8905 Backup LTC 8910 Main LTC 8910 Backup Main Power Power CPU Module CPU Module Supply Supply LTC 8808 Video Panels...
  • Page 81 LTC 8900 Series Satellite System Configuration Installations | en PC Running Configuration Software Additional Additional Additional Additional Cameras Cameras Cameras Cameras LTC 8905 LTC 8905 Backup LTC 8910 Main LTC 8910 Backup Main Power Power CPU Module CPU Module Supply...
  • Page 82 | Satellite System Configuration Installations LTC 8900 Series Figure 8.28: Video Bus Concept Diagram 2015.01 | 10.6 | Installation Manual Bosch Security Systems, Inc.
  • Page 83 LTC 8900 Series Satellite System Configuration Installations | en Figure 8.29: Module, Termination, and Interconnect Cabling for 256 Cameras by 32 or 64 Monitor Systems Bosch Security Systems, Inc. Installation Manual 2015.01 | 10.6 |...
  • Page 84 | Satellite System Configuration Installations LTC 8900 Series Figure 8.30: Module, Termination, and Interconnect Cabling for 512 Camera by 32 or 64 Monitor System 2015.01 | 10.6 | Installation Manual Bosch Security Systems, Inc.
  • Page 85 LTC 8900 Series Satellite System Configuration Installations | en LTC 8902 16 LTC 8921 Video Input 16 LTC 8921 Video Input 16 LTC 8921 Video Input Modules are Required for Modules are Required for Modules are Required for Camera Inputs 1 to 256...
  • Page 86 | Satellite System Configuration Installations LTC 8900 Series LTC 8902 16 LTC 8921 Video Input 16 LTC 8921 Video Input 16 LTC 8921 Video Input 16 LTC 8921 Video Input Modules are Required for Modules are Required for Modules are Required for...
  • Page 87 LTC 8900 Series Satellite System Configuration Installations | en 16 LTC 8921 Video Input 16 LTC 8921 Video Input 16 LTC 8921 Video Input 16 LTC 8921 Video Input 16 LTC 8921 Video Input Modules are Required for Modules are Required for...
  • Page 88 | Satellite System Configuration Installations LTC 8900 Series 16 LTC 8921 16 LTC 8921 16 LTC 8921 16 LTC 8921 16 LTC 8921 16 LTC 8921 16 LTC 8921 Video Input Video Input Video Input Video Input Video Input...
  • Page 89 LTC 8900 Series Satellite System Configuration Installations | en 16 LTC 8921 Video Input 16 LTC 8921 Video Input 16 LTC 8921 Video Input 16 LTC 8921 Video Input Modules are Required for Modules are Required for Modules are Required for...
  • Page 90 | Satellite System Configuration Installations LTC 8900 Series Monitors 1–32 Monitors 33–64 Upper Lower LTC 8809 Group Inputs 3 and 4 are LTC 8809 Ribbon Ribbon used for additional LTC 8903 Cable Cable Camera Bay Connections Each Line Represents an...
  • Page 91 LTC 8900 Series Satellite System Configuration Installations | en System Cameras Connect to the First Level LTC 8903 Video Input Bay 16 LTC 8921 Video Input Modules are Required for Cameras 1 to 256 LTC 8902 for Monitors 1 to 64...
  • Page 92 | Satellite System Configuration Installations LTC 8900 Series System Cameras Connect to First Level LTC 8903 Video Input Bay 16 LTC 8921 Video Input Modules are Required for Cameras 1 to 256 LTC 8902 for Monitors 1 to 64...
  • Page 93 LTC 8900 Series Satellite System Configuration Installations | en System Cameras Connect System Cameras Connect to the First Level LTC 8903 to the First Level LTC 8903 Video Input Bay Video Input Bay 16 LTC 8921 Video Input 16 LTC 8921 Video Input...
  • Page 94 | Satellite System Configuration Installations LTC 8900 Series Figure 8.40: Front View, Module Placement and Termination Settings, 1024 Camera by 96 Monitor System 2015.01 | 10.6 | Installation Manual Bosch Security Systems, Inc.
  • Page 95 LTC 8900 Series Satellite System Configuration Installations | en Figure 8.41: Front View, Module Placement and Termination Settings, 1024 Camera by 128 Monitor System Bosch Security Systems, Inc. Installation Manual 2015.01 | 10.6 |...
  • Page 96 | Satellite System Configuration Installations LTC 8900 Series 2015.01 | 10.6 | Installation Manual Bosch Security Systems, Inc.
  • Page 97 LTC 8900 Series Satellite System Configuration Installations | en Figure 8.42: Front View, Module Placement and Termination Settings, 2048 Camera by 96 Monitor System Figure 8.43: Front View, Module Placement and Termination Settings, 2048 Camera by 128 Monitor System Bosch Security Systems, Inc.
  • Page 98: Troubleshooting Guide

    | Troubleshooting Guide LTC 8900 Series Troubleshooting Guide The LTC 8900 Allegiant system was designed to provide very high reliability. However, if a failure does occur, the effects of the failure depend on system design and the location of the failure.
  • Page 99 LTC 8900 Series Troubleshooting Guide | en Limited keyboard functions If possible, perform a local keyboard test to verify operation of all keys. If a local test cannot be performed, replace the keyboard. The installer or system administrator should review the PC-based configuration software package s lockout tables to determine if the problem is related to user restriction tables.
  • Page 100 | Troubleshooting Guide LTC 8900 Series CPU and Data Receiver LED Indicators: PCB ID PCB Label Color Function D1000 RESET Lit during reset condition D0908 CPU ACT. Green Flashes to indicate processor activity D0909 BATT LOW Lit when battery is low...
  • Page 101: Maintenance Information

    LTC 8900 Series Maintenance Information | en Maintenance Information NOTE: The LTC 8900 Allegiant system has been designed to perform for long periods of time with little or no maintenance. Cleaning the keyboard or replacing a fuse may be necessary occasionally.
  • Page 102: Matrix Bay Ac Line Fuse Replacement

    | Maintenance Information LTC 8900 Series Figure 10.2: Line Voltage Selector Removal 10.3 Matrix Bay AC Line Fuse Replacement The AC line fuse on LTC 8805/60 and LTC 8906/60 Power Supply models is located on the rear of the equipment bay, near the line cord connector. LTC 8805/50 and LTC 8906/50 Power Supply models (220-240VAC input versions) contain a circuit breaker equipped power switch that can be reset from the front.
  • Page 103: Matrix Bay Power Supply Fuse Replacement

    LTC 8900 Series Maintenance Information | en Remove the fuse from the holder (as in , page 102), and replace it with a fuse of the same rating (1.6 A, 250 V) for continued protection. Reinstall the fuse holder into the connector housing in the same orientation as indicated by the arrow on the door cover.
  • Page 104: Ltc 8943/95 System Controller Pc

    | Maintenance Information LTC 8900 Series Wait for the System Supervisor to indicate that the Data Mirroring process has completed. This step takes a few minutes. From the System Supervisor software, change the In Use CPU to the Primary CPU. This moves control to the new LTC 8901 Series CPU bay.
  • Page 105 LTC 8900 Series Maintenance Information | en The two batteries are mounted on the front edge of the CPU card and are about 25 mm (1 in.) in diameter. Insert a small flat blade screwdriver into the slot on one of the battery holder sockets and gently pry the battery from the holder until it can be removed by your fingers.
  • Page 106: Pinouts

    B.1.6 COMM PORT 1 and COMM PORT 2 LTC 8900 Series CPU Bay Rear Panel Pin # ..... .Designation Connector Pinouts 1 .
  • Page 108 Bosch Security Systems, Inc. Bosch Sicherheitssysteme GmbH 850 Greenfield Road Robert-Bosch-Ring 5 Lancaster, PA, 17601 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Security Systems, Inc., 2015...