Deviation Dectector Side Section
Deviation Default Value
4-22
How to Adjust
1. Loosen the nuts.
2. Adjust the proximity sensor until the blade deviation
3. Tighten the nuts.
How to Check
the value of
compensatory
value shown the display returns to zero.
Put a thick ruler (0.1mm) between saw blade and
deviation roller for measurement.
deviation tilt value; it should be 0.1mm. If not 0.1mm,
please adjust the value of compensatory till as same value
as the value of tilt and the thick ruler, 0.1mm. (Please refer
to the next page, picture A.)
Adjust the proximity sensor until the blade deviation
displayed on the control panel is zero.
If the deviation value not changed when adjusting the
proximity sensor or bearing, it means the deviation
detector with malfunction. Need to replace a new
one.
Please clean the internal shell of deviation detector
sometimes for keeping dry and clean.
Picture A :
Before shipping:
Make the proximity sensor connect
with power & adjust the proximity
sensor until the blade deviation
displayed on the control panel is 0 mm
& AD2-1 value as 2048.
Adjust saw arm until AD2-1 value as
2048.
This page for system parameters.
Password is required.
All parameters have been set up by
the manufacturer. In order to prevent
random change from being made to these
parameters and affect cutting precision and
machine life, this function is protected with
a set of password.