Mitsubishi Electric FR-F806-E Hardware Instruction Manual page 58

Inverter for fans and pumps, ip55/ul type 12
Table of Contents

Advertisement

2.9.6
Connection of the power regeneration converter
(MT-RC)
When connecting the power regeneration converter (MT-RC), perform wiring securely as shown below. Incorrect connection
will damage the power regeneration converter and the inverter. The MT-RC is applicable to FR-F846-01800(75K) or higher.
After making sure that the wiring is correct, set "1" in Pr.30 Regenerative function selection.
MCCB
Three-phase
AC power
supply
NOTE
• When using the inverter with the MT-RC, install a magnetic contactor (MC) at
the input side of the inverter so that power is supplied to the inverter after 1 s or
more has elapsed after powering ON the MT-RC. When power is supplied to
the inverter prior to the MT-RC, the inverter and the MT-RC may be damaged
or the MCCB may trip or be damaged.
• When connecting the power coordination reactor and others, refer to
Instruction Manual of the MT-RC for precautions.
MC2
MC1
MT-RCL
R
R2
S
S2
T
T2
Connection of stand-alone option units
Inverter
U
R/L1
M
V
S/L2
W
T/L3
R1/L11
S1/L21
P/+
N/-
Reset signal
P
N
RES
R2
STF
S2
SD
T2
C
B
R
A
S
RDY
T
R1
Ready signal
SE
S1
MT-RC
Inverter input power
supply (MC2)
MT-RC power
supply (MC1)
INSTALLATION AND WIRING
Alarm signal
ON
ON
1s or more
2
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents