Component names
Component names are shown below. (Example: FR-F846-00250(11K))
Front cover for
control circuit
inspection
Front cover for
main circuit
inspection
Front cover of the
FR-F846-01800(75K) or higher
(o)
(n)
Symbol
Name
(a)
PU connector
(b)
USB A connector
(c)
USB mini B connector
(d)
Plug-in option connector 1
(e)
Plug-in option connector 3
(f)
Plug-in option connector 2
Voltage/current input switch
(g)
(SW2)
(h)
Control circuit terminal block
(i)
EMC filter ON/OFF connector
(j)
Charge lamp
Ethernet communication
(k)
connector
(l)
Main circuit terminal block
(m)
Wiring cover
(n)
Front cover
(o)
Operation panel (FR-LU08-01) Operates and monitors the inverter.
(p)
Fan cover
(q)
Cooling fan
(r)
Internal fan
(s)
Bracket
(t)
Protective cover
Switches for manufacturer
(u)
setting (SW3 and SW4)

Refer to the FR-F800 Instruction Manual (Detailed)
(p)
(q)
(t)
(s)
(r)
(m)
Connects the operation panel or the parameter unit. This connector also enables
the RS-485 communication.
Connects a USB memory device.
Connects a personal computer and enables communication with FR Configurator 2.
Connects a plug-in option or a communication option.
The connector 2 cannot be used because the Ethernet board is installed in the
initial status. The Ethernet board must be removed to install a plug-in option to the
connector 2. (However, Ethernet communication is disabled in that case.)
Selects between voltage and current for terminal 2 and 4 inputs.
Connects cables for the control circuit.
Turns ON/OFF the EMC filter.
Stays ON while the power is supplied to the main circuit.
Connect the Ethernet dedicated cable for connection to the network.
Connects cables for the main circuit.
Remove the protective bushes to connect cables. (FR-F846-00470(22K) or lower)
Remove this cover for the installation of the product, installation of a plug-in
(communication) option, switching of the voltage/current input switch, etc. For the
FR-F846-01800(75K) or higher, the front cover for the control circuit inspection and
the front cover for the main circuit inspection can be individually removed.
Remove this cover for replacement of the cooling fan. (FR-F846-00250(11K) or
higher)
Cools the inverter. (FR-F846-00250(11K) or higher)
Cools the inverter.
Fixes the internal fan.
Protects the fan to avoid contacting the wiring. (FR-F846-00250(11K) to 00470(22K))
Do not change the initial setting (OFF
(a)
(d)
(f)
(g)
(j)
(i)
(l)
Description
).
OFF
ON
INTRODUCTION
Component names
(e)
(b)
(c)
(u)
(k)
(h)
Refer to
page
47
49
49
Instruction
Manual of
the option
48

32
64
25
48
25
15
15
44
85
85
91
91
92
9
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents